operate a crane, hoist or lifting device if the chain or wire rope is not seated properly in the 
sprockets, drum or sheave 

 

 

operate any damaged or malfunctioning crane, hoist, lifting device or other material handling 
equipment 

 

 

change any settings or controls without authorization and proper training 

 

 

remove or obscure any warning or safety labels or tags 

 

 

leave any load unattended while lifted  

 

 

leave power on the radio controlled equipment when the equipment is not in operation 

 

 

operate any material handling equipment using a damaged controller because the unit may be 
unsafe 

 

 

operate manual motions with other than manual power   

 

 

operate radio controlled equipment when low battery indicator is on  

 

 

 

WARNING

 

THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER. IF ANY PRODUCT 
PERFORMANCE OR SAFETY CONCERNS ARE OBSERVED, THE EQUIPMENT SHOULD 
IMMEDIATELY BE TAKEN OUT OF SERVICE AND BE REPORTED TO THE SUPERVISOR. DAMAGED 
AND INOPERABLE RADIO CONTROLLER EQUIPMENT SHOULD BE RETURNED TO MAGNETEK FOR 
EVALUATION AND REPAIR. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS 
INJURY OR DEATH AND DAMAGE TO EQUIPMENT.

 

 

 

2.4 

PRE-OPERATION TEST  

 

At the start of each work shift, or when a new operator takes control of the crane, operators should do, as a 
minimum, the following steps before making lifts with any crane or hoist:  

Test all warning devices. 

Test all direction and speed controls. 

Test the receiver emergency stop.

 

Содержание Enrange CAN-6

Страница 1: ...CAN 6 Enrange CAN 6 Radio Receiver September 2011 Part Number 198 00244 1000 R1 Copyright 2011 Magnetek Material Handling...

Страница 2: ...288 8178 Website www magnetekmobilehydraulic com e mail info magnetekmh com Fax Numbers Main 1 800 298 3503 Sales 1 262 783 3510 Service 1 262 783 3508 Canada Service Information 4090B Sladeview Cresc...

Страница 3: ...IN OUT DIAGRAM AND DEFINITIONS 11 3 6 CAN 6 RECEIVER BLOCK DIAGRAM 13 4 0 CONFIGURING THE CAN 6 14 4 1 SETTING ANTENNA TYPE 14 4 2 REMAINING BANK 1 DIP SWITCH SETTINGS 14 4 3 RECEIVER CHANNEL CONFIGUR...

Страница 4: ...tions in this manual do not take precedence over any of the following requirements relating to cranes hoists and lifting devices Instructions manuals and safety warnings of the manufacturers of the eq...

Страница 5: ...intenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as shown below CAUTIO...

Страница 6: ...OF THIS PRODUCT ARE NOT DESIGNED TO INTERFACE DIRECTLY TO TWO STATE SAFETY CRITICAL MAINTAINED FUNCTIONS I E MAGNETS VACUUM LIFTS PUMPS EMERGENCY EQUIPMENT ETC A MECHANICALLY LOCKING INTERMEDIATE RELA...

Страница 7: ...g devices prior to operation testing should be done on each shift without a load be thoroughly trained and knowledgeable in proper and safe operation of the crane hoist lifting device or other materia...

Страница 8: ...rate manual motions with other than manual power operate radio controlled equipment when low battery indicator is on WARNING THE OPERATOR SHOULD NOT ATTEMPT TO REPAIR ANY RADIO CONTROLLER IF ANY PRODU...

Страница 9: ...IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT 3 1 PRE INSTALLATION 1 The transmitter and receiver access code and channel must match before the system will communicate 2 Be aware of other radio c...

Страница 10: ...uction Manual September 2011 Page 9 of 24 Figure 02 CAN 6 with external antenna red Figure 03 CAN 6 900 MHz version only with internal antenna red Figure 04 CAN 6 with Con1 and Con2 connectors Figure...

Страница 11: ...ld be fused NOTE Magnetek strongly recommends the use of external fuses and circuit disconnects for all CAN 6 Receivers Consult factory for more information 3 4 REMOVAL OF CAN 6 FROM HOUSING Rarely it...

Страница 12: ...Enrange CAN 6 Instruction Manual September 2011 Page 11 of 24 3 5 PIN OUT DIAGRAM AND DEFINITIONS Figure 06 Pin out diagram...

Страница 13: ...oss of communications the machine stop output will be enabled Figure 07 CAN 6 Machine Stop Wiring Additionally make sure that a Machine Stop is provided elsewhere on the equipment in which the CAN 6 i...

Страница 14: ...anual September 2011 Page 13 of 24 3 6 CAN 6 RECEIVER BLOCK DIAGRAM NOTE Connections are labeled by which side the connector is on the CAN 6 receiver i e L1 is pin 1 on the left connector R1 is pin 1...

Страница 15: ...e selected from internal to external on the CAN 6 module by utilizing SW8 on the Bank 1 dip switches Antenna Type SW8 Internal Up External Down NOTE If the CAN 6 module is installed inside an enclosur...

Страница 16: ...H BANK 2 The channel can be set on the CAN 6 receiver via the Bank 2 dip switches The following sections Sections 4 3 1 through 4 3 3 show the channels or protocols available for each radio frequency...

Страница 17: ...Enrange CAN 6 Instruction Manual September 2011 Page 16 of 24 4 3 1 Channel Dip Switch Settings for 900MHz Part 15...

Страница 18: ...Enrange CAN 6 Instruction Manual September 2011 Page 17 of 24 4 3 2 Channel Dip Switch Settings for 433MHz Part 15...

Страница 19: ...Enrange CAN 6 Instruction Manual September 2011 Page 18 of 24 4 3 3 Channel Dip Switch Settings for 2 4GHz 50mW and 125mW...

Страница 20: ...cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly...

Страница 21: ...strength and error code status as part of the normal operation 5 2 NORMAL OPERATION During normal operation of the receiver the receiver will receive commands from the transmitter and convert them in...

Страница 22: ...RF Data Timeout Red 4 Blinks CANbus Timeout Refer to Section 6 0 for the troubleshooting table to interpret error codes NOTE SIGNAL STRENGTH ERROR CODE LED only illuminates green when the receiver is...

Страница 23: ...eiver location If equipped with the Signal Strength Indicator make sure the level is greater than 0 The antenna on the receiver is missing damaged or improperly installed Inspect the antenna on the re...

Страница 24: ...er is set correctly The termination resistor is set incorrectly Ensure the termination resistor is appropriately set Incorrect baud rate Ensure the correct baud rate is set by all devices on the bus O...

Страница 25: ...er ever needs repair we always recommend that you have Magnetek perform the repair If you need to refer to a parts list refer to your receiver s drawing that was included in the shipment of your recei...

Отзывы: