![MAGNET-SCHULTZ GBRE 022 AMX E02 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/magnet-schultz/gbre-022-amx-e02/gbre-022-amx-e02_operating-manual_3559356008.webp)
Operating Manual BA012160-001
Revised: 18.05.2010
Page 4 of 4
Technical Data
Manufacturer
Magnet-Schultz GmbH & Co. KG
87700 Memmingen / Germany
www.magnet-schultz.com
valve solenoid-type
GBRE 022 AMX E02
date of production
refer to device-labelling
assembly
variant W
knurled nut / spring washer
armature tube (not in delivery)
MSM 231743 / MSM 631275
** FPB
(** corresponds to the date of production)
rated voltage ±10%
U
N
24 V AC
110 V AC
230 V AC
frequency
f
50 Hz to 60 Hz
50 Hz to 60 Hz
50 Hz to 60 Hz
rating current
I
B
0.216 A
0.044 A
0.022 A
limiting power
P
G
4.4 W
4.4 W
4.2 W
limitation of transient overvoltages
bridge rectifier and unidirectional diode
temperature class
T5
-20 °C to +40 °C
ambient temperature
T
a
for function of the armature tube in accordance with specification of the armature tube
within above temperature range
surface temperature
95 °C
greater/equal 25 mm x 25 mm x 17 mm in Al
single mounting
with valve
or with mounting plate
and valve
greater/equal 27 mm x 29 mm x 2 mm in Fe
greater/equal 32 mm x 32 mm x 22 mm in plastic
butt mounting
with valve
on single valve
with terminal strip
distance wall to wall
in plastic or Al
greater/equal 45 mm x 26 mm x 83 mm in Al
cross section: greater/equal 32 mm x 20 mm in Al
or material with same/better thermal conductivity
greater/equal 5 mm
connection cable
type 4 GMH 4 G – J 3 x 0,75 mm²
or H05 GG – F3G 0,75 mm²
short circuit protection:
A fuse corresponding to the rating current (max. 3 x I
B
acc. to IEC/EN 60127-2) or a motor-protection-
switch with short circuit and thermal rapid release respectively (corresponding to rated current) have
to be connected in series to each valve solenoid. This fuse may be located in the accessory power
supply unit or has to be connected in series separately.
terminal for earth connection
up to 4 mm²