background image

LT80-NE

Operating Manual

Display Unit

Read all the instructions in the manual carefully before use and strictly follow them. 
Keep the manual for future references.
This manual corresponds to the software version Ver 1.05.00JP.
This manual describes only the added and changed functions compared to the software version 
Ver 1.04.00, so be sure to also read the software version Ver 1.02.00/1.04.00 Operating Manual.

Содержание LT80-NE

Страница 1: ...rictly follow them Keep the manual for future references This manual corresponds to the software version Ver 1 05 00JP This manual describes only the added and changed functions compared to the softwa...

Страница 2: ...so supports frames with a calculation set Display value Measurement display value Set magnification 3 Preset settings for frames with a calculation set P 4 Preset values can be set for frames with a c...

Страница 3: ...ution of the measuring unit corresponding to that frame cannot be selected When the display resolution has been changed redo the comparator value preset value and reference point preset value settings...

Страница 4: ...measuring units using calculations View frame settings screen The Scaling column displays the results of multiplying the measurement display values by the set magnification Display value Measurement d...

Страница 5: ...s with a calculation set Starting from this version preset values can also be set for frames with a calculation set View frame settings screen Touch inside the frame and use the numerical keypad to en...

Страница 6: ...save setting Clear measurement data saved in display unit Device selection Touch this button to select the external device for import and export operation Data type selection Touch this button to sele...

Страница 7: ...Exports setup parameters and measurement data from the display unit to an external memory Follow the instructions in the pop up message to perform import and export operation Example Operation to imp...

Страница 8: ...ata menu when reading measurement data Examples of selectable date and time formats Selection of Decimal points The delimiter in the data format is a comma when dot is selected or a semicolon when com...

Страница 9: ...he number of data can be set up to 300000 When auto save by number of data is selected export operation is performed during measurement and a progress bar such as the following is displayed while expo...

Страница 10: ...n auto mode is reached but note that measurement operation stops while save is in progress Input Selection symbol Description Function Terminal logic SaveMeas Data save Saves the acquired cache data i...

Страница 11: ...r operation The button text color changes to gray after power on after settings are changed and after latch operation ends the set latch count is reached Normal operation can be performed Latch operat...

Страница 12: ...ent l usage des acqu reurs de l quipement d crit dans ce manuel Magnescale Co Ltd interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des op...

Страница 13: ...Isehara shi Kanagawa 259 1146 Japan 1 16 16 For foreign customers Note This product or technology may be restricted by the government in your country Please make sure that end use end user and country...