LT20A / LT30 Series
e
Measuring unit input
: SIG. IN A
r
Measuring unit input
: SIG. IN B (2 channel models)
ty
BCD Output
With the 2 channel models the upper and lower
selections of the front panel’s main display correspond
to the BCD OUT. A/BCD OUT. B. So if “A+B” is
selected the output is to BCD OUT. A.
The following operations are possible when BCD
input/output terminal is used.
Input : Comparator value selection (4 settings),
measuring mode (current value, maximum value,
minimum value, peak-to-peak values) selection
Output : 6 digits
Outputs one of the current, maximum,
minimum, and peak-to-peak values selected
via the keys on the front panel and the
external input.
Alarm output
u
RS-232C interface
(See “9. RS-232C Interface”.)
Reset, peak-hold start, setting/recall of preset values,
setting the comparator value, selecting and outputting
the current value/maximum value/minimum value/
peak-to-peak value.
4-3. Function description
4-3-1. Reset key
Counter unit
Measuring mode
(Current value, maximum
value, minimum value,
peak-to-peak value)
Preset mode
(
P
and the selected digit
will flash.)
“Error” is displayed
Operation performed when reset
key is pressed
•
For the setting which does not
use the reference point
Display is set to zero.
When a preset value has been set,
it is recalled.
(Except when the Measuring mode
is set to peak-to-peak value)
•
For the setting which uses the
reference point
A t t h e p r e s s o f t h e k e y , t h e
maximum and minimum values will
be set to the current value (peak-
to-peak value = 0). When the key
remains pressed for two seconds,
the unit is set to the reference point
signal input wait satatus.
Preset value is set to zero.
•
For the setting which does not
use the reference point
“ E r r o r ” i s c a n c e l e d a n d t h e n
returnes to the measuring state.
•
For the setting which uses the
reference point
“Error” is canceled and the unit
enters the reference point signal
input wait status.
Содержание LT20A Series
Страница 3: ...J 1 LT20A LT30 Series...
Страница 4: ...2 J LT20A LT30 Series I O DC I O AC...
Страница 7: ...J 1 LT20A LT30 Series 1 1 1 1 2 DC DC I O AC I O BCD...
Страница 11: ...J 5 LT20A LT30 Series 3 1 3 2 1 2 2 3 4 Min 30 mm 3 3 2 1 4 R1 68 1 0 0 4 68 1 0 0 4 BOX Max 12 3 30...
Страница 18: ...12 J LT20A LT30 Series 4 3 6...
Страница 25: ...J 19 LT20A LT30 Series 10 RS 232C MODE 5 2 5 2 1 1 P A CH P A SET P MODE COMP 1 4 7 3 6 2 5 RESET B RESET A...
Страница 29: ...J 23 LT20A LT30 Series 5 2 4 1 5 1 5 mm M A X M I N P P C P L1 2 3 4 P B...
Страница 30: ...24 J LT20A LT30 Series 1 mm 2 1 mm 3 4 5 2 1 1 mm 2 I O 2 RS 232C L 1 1 6 A...
Страница 38: ...32 J LT20A LT30 Series 8 3 8 7 mm 2 m GND FG 5 6 I N DATA OUT MAX 0 2 ms 50 50 READY OUT BCD Data OUT...
Страница 54: ...48 J LT20A LT30 Series 12 1 ON 6 F 5 ON...
Страница 56: ...50 J LT20A LT30 Series...
Страница 166: ......
Страница 167: ...1 z q w x q w e r t c v b LT20A LT30 Series...