Maintenance
Repair
MagneMover LITE User Manual
43
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
AC Fuse
1.
Turn off power to the MM LITE Power Supply and unplug the power cable.
2.
Open the Power Entry Module (PEM), shown in
, by inserting a small flat
blade screwdriver into the slot at the top and pressing outward as shown in
Figure 7-14: Open the Power Entry Module
3.
Remove the fuse module from the PEM by inserting a small flat blade screwdriver into
the slot at the top and pressing outward as shown.
Figure 7-15: Remove the PEM Fuse Module
4.
Remove the old fuse.
5.
Install a new fuse.
6.
Insert the fuse module into the PEM ensuring that it is oriented correctly.
Fuse Type
Fuse Location
T, 250V, 2A
Single fuse on the right-hand side.
Single fuse on the left-hand side.
NOTICE
Never force the Fuse Module
when inserting. Ensure it is not at an
angle prior to inserting and slides straight in.