Maintenance
Repair
36
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Procedure
Figure 7-10: Remove Curve Motor Guide Rail
Remove Pucks
1.
Stop all motion on the section of the MagneMover LITE transport system where the
puck will be removed.
2.
Remove the inside guide rail from a curve motor.
A.
Remove the two screws securing the V-braces to the guide rail.
B.
Remove the two screws securing the guide rail to the motor.
C.
Lift the guide rail off of the motor.
3.
Remove pucks by sliding them from the adjacent motors into the open curve.
NOTE:
Once pucks are removed from the transport system they must be stored in
their original packaging to protect the pucks and to minimize any safety
risks.
4.
Replace the guide rail by reversing
.
A.
Apply Loctite 243 to the screws.
B.
Tighten the guide rail mounting screw and the V-brace hardware to 3.4 N-m
[30 in-lb].
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the
transport system.
5.
Return the MM LITE transport system to normal operation.