Installation
Transport System Installation
MagneMover LITE User Manual
39
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
1.
Connect a power cable to either the J1 or J2 terminals on the power supply. Refer to
the labels on the wires to identify the correct connections (refer to
).
2.
Run the power cable from the power supply to the first motor in the Path, routing the
cable in the cable chase.
3.
Connect a T-splitter power cable to the motor; finger-tighten – do not use tools to
tighten.
4.
Connect the power cable to the T-splitter power cable; finger-tighten – do not use tools
to tighten.
5.
Connect a power bus cable to the T-splitter; finger-tighten – do not use tools to tighten
and route the cable in the cable chase.
6.
Connect a T-splitter power cable to the next motor; finger-tighten – do not use tools to
tighten.
7.
Connect the power bus cable from the last motor to the T-splitter; finger-tighten – do
not use tools to tighten.
8.
Repeat
for each motor in the power chain.
NOTE:
It is not necessary to connect all of the motors on a Path to the same power
supply or to connect a power supply to only one Path.
9.
Install a power bus end cap at the end of each power run to seal the cable; fin-
ger-tighten – do not use tools to tighten.
10.
Connect the Ground stud on all NC-12 Node Controllers to GND (PE).
11.
Bundle and dress all cables (use nylon cable-ties) as needed to ensure clean cable rout-
ing.
12.
for external power connections.