2.1 Delivery Control
Symbols and their meanings on the device;
2.2 Installation And Operation Recommendations
Make sure you have received your order in full. If any material is missing or damaged, contact your place of purchase immediately.
The standard box includes the following;
• Power Source
• Transportation Belt
• Earth Clamp Cable
• User Manual
• TIG Torch Plug
In the case of a damaged delivery, draw up a record, take a picture of the damage and report to the transport company together with a photocopy of
the delivery note. If the problem persists, contact the customer service.
For better performance, place the machine at least 30 cm away from the surrounding objects. Pay attention to overheating, dust and moisture near
the machine. Do not operate the machine under direct sunlight. If the ambient temperature exceeds 40°C, operate the machine at a lower current or
a lower operating cycle.
Avoid welding outdoors in windy and rainy weather circumstances. If welding is necessary in such cases, protect the welding area and the welding
machine with a curtain and canopy.
If you weld indoors, use a suitable smoke extraction system. Use breathing apparatus if there is a risk of inhaling welding fumes and gas in confined
spaces.
Observe the operating cycle rates specified on the product label. Suspending operating cycle rates can damage the machine and this may invalidate
the warranty. Use the fuse that is compliant with your system.
Tighten the ground wire as close as possible to the welding area. Do not allow the welding current to pass through equipment other than the
welding cables.
If TIG is to be applied with a plug torch, secure the gas cylinder in a way not causing any hazards.
The welding cables and the mains cable must not be wrapped in the machine housing during operation.
Welding process is dangerous. Proper working conditions should be ensured and necessary precautions should be taken. Specialists are
responsible for the machine and have to be equipped with the necessary equipment. Irrelevant persons should be kept away from the
welding area.
This device is not compatible with IEC 61000-3-12. If it is desired to connect to the low voltage mains used in homes, it is essential that
the installer or the person who will operate the machine to make the electrical connection has information on the machine’s connectivity.
In this case the responsibility will be assumed by the person who will perform the installation or by the operator.
The safety symbols and warning notes on the device and in the operating instructions must be observed and the labels must not be
removed.
Grids are intended for ventilation. The openings should not be covered in order to provide good cooling and no foreign objects should be
inserted.
INSTALLATION
Installation
Содержание Monotig 160ip
Страница 48: ...48 www magmaweld com USER MANUAL KULLANIM KILAVUZU TR Monotig 160ip EK 2 DEVRE EMASI Ek 2 Devre emas...
Страница 50: ......
Страница 51: ......