background image

 

Prisma Wash 100

 

User Manual

 

 

Содержание Prisma Wash 100

Страница 1: ...Prisma Wash 100 User Manual...

Страница 2: ...ssional B V Junostraat 2 6468 EW Kerkrade The Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu Elation Professional Mexico AV Santa Ana 30 Parque Industri...

Страница 3: ...tion 4 Limited Warranty USA Only 5 Safety Guidelines 7 Maintenance Guidelines 9 Fixture Overview 10 Installation Instructions 11 System Menu 13 DMX Channel Functions Values 14 Dimmer Modes 19 Specific...

Страница 4: ...ce to your dealer without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Mounting Bracket x1 Locking Power Cable...

Страница 5: ...instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magm...

Страница 6: ...ed freight pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of...

Страница 7: ...e risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID...

Страница 8: ...cord by the plug end never pull out the plug by tugging the wire portion of the cord During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This...

Страница 9: ...vice technician Should you need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check b...

Страница 10: ...U R E O V E R V I E W 1 Tilt Lock 2 Lens 3 Power In 4 Power Out 5 Display Screen 6 Mode Button 7 Up Button 8 Down Button 9 Enter Button 10 DMX Out 11 DMX In 12 Safety Cable Rigging Points 13 Omega Bra...

Страница 11: ...gns to any metal truss structure or placing the fixture s on any surface a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified...

Страница 12: ...o the safety cable rigging point RIGGING Overhead rigging requires extensive experience including but not limited to calculating working load limits understanding the installation material being used...

Страница 13: ...h the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN but...

Страница 14: ...6 CH FUNCTION No DMX Black Hold LCD Set Display 30s screen time out On Off Key Lock On Off Flash On Off Invert flip screen 180 Off On Temp C F C F Dim Mode Standard Stage TV Architec Theatre Stage2 0...

Страница 15: ...DFSE Password 050 On Off Restore to factory default settings INFO TimeInfo Current Current fixture run time Hrs Total Fixture total run time Hrs Last Run time since last clear event Hrs Clear Password...

Страница 16: ...e slow to fast 096 127 Open 128 159 Pulse slow to fast 160 191 Open 192 223 Random Strobe slow to fast 224 255 Open 1 2 2 000 255 Dimmer 0 255 Master Dim 2 3 3 000 255 Dimmer Fine 0 255 16bit 4 Dim Mo...

Страница 17: ...9 029 1080 Hz LED Refresh Rate 030 030 1090 Hz LED Refresh Rate 031 031 1100 Hz LED Refresh Rate 032 032 1110 Hz LED Refresh Rate 033 033 1120 Hz LED Refresh Rate 034 034 1130 Hz LED Refresh Rate 035...

Страница 18: ...e 066 066 1460 Hz LED Refresh Rate 067 067 1470 Hz LED Refresh Rate 068 068 1480 Hz LED Refresh Rate 069 069 1490 Hz LED Refresh Rate 070 070 1500 Hz LED Refresh Rate 071 071 2500 Hz LED Refresh Rate...

Страница 19: ...D I M M E R M O D E S Select desired DIMMER MODE Standard Stage TV Architectural Theatre Stage2 Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURV...

Страница 20: ...Housing Manual Adjustable Tilt Position CONTROL Multiple DMX Channel Modes Onboard 4 Button Touch Control Panel DMX 512 and RDM Protocol Support CONNECTIONS Locking 5pin XLR Connector In Out IP65 Lock...

Страница 21: ...21 D I M E N S I O N A L D R A W I N G S Drawings not to scale ORDERING SKU PSW300 EU 1237000237 UPC 810008261040 OPTIONAL ACCESSORIES PRISMA WASH BLACK GLASS PSG800...

Страница 22: ......

Отзывы: