background image

INTRODUCTION

Please read and understand the instructions in this manual carefully and thoroughly before attempting 

to operate this device. These instructions contain important safety and use information.

This product is intended to be used by professionally trained personnel only and is not suitable 

for private use.

UNPACKING

Every device has been thoroughly tested and has been shipped in perfect operating condition. Care-

fully check the shipping carton for damage that may have occurred during shipping. If the carton is 

damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and 

operate the device have arrived intact. In the event that damage has been found or parts are missing, 

please contact our customer support team for further instructions. Please do not return this device to 

your dealer without first contacting customer support. Please do not discard the shipping carton in the 

trash. Please recycle whenever possible.

BOX CONTENTS

Phoenix Connector (x1)

Positive Wire Tip Sheath (x1)

Negative Wire Tip Shealth (x1)

CUSTOMER SUPPORT

Contact MAGMATIC customer service for any product related service and support needs.

Also visit 

forums.elationlighting.com

 with questions, comments, or suggestions.

ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST

323-582-3322 | Fax 323-832-9142 | 

[email protected]

ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET 

Voice: +31 45 546 85 63 | Fax: +31 45 546 85 96 | 

[email protected]

REPLACEMENT PARTS: Please visit 

parts.elationlighting.com

GENERAL INFORMATION

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY 

REPAIRS YOURSELF. DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAM-

AGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF 

SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S 

WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

IMPORTANT NOTICE!

4

Содержание PRISMA MINI BAR 20

Страница 1: ...User Manual PRISMA MINI BAR 20 US SKU PSB121 UPC 810008261187 ITF 14 10810008261184...

Страница 2: ...Please check www elationlighting com for the latest revision update of this manual before beginning installation and or programming MAGMATIC EFFECTS 6122 S Eastern Ave Los Angeles CA 90040 323 582 33...

Страница 3: ...3 General Information 4 Limited Warranty USA Only 5 Warranty Returns USA Only 6 Safety Guidelines 7 Maintenance Guidelines 9 Overview 10 Installation Instructions 11 Specifications 14 Dimensional Dra...

Страница 4: ...customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Phoenix Connector x1 Positive Wire Tip Sheath x1 Negative Wire Tip Shealth x1 CUST...

Страница 5: ...anual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magmatic Effects will replace defective pa...

Страница 6: ...pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of the probl...

Страница 7: ...age and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFAC...

Страница 8: ...NEVER pull out the plug by tugging the wire portion of the cord During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process a...

Страница 9: ...nician Should you need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check by an appr...

Страница 10: ...1 Lens 2 Bracket Adjustment Screw x2 3 Mounting Bracket x2 4 Safety Cable Attachment Point x2 5 Power Data Cable OVERVIEW 10...

Страница 11: ...equipment in staller MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the fixture s clamps cables and accessories Ambi...

Страница 12: ...ABLES of the ap propriate rating to each of the safety cable attachment points SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING THIS FIXTURE IN A SUSPENDED EN VIRONMENT TO ENSURE THAT THE FIX...

Страница 13: ...sion filters SKU PSG820 for full coverage of the lens To install the black glass filters simply align the screw holes on the the black glass filters with the matching screw holes on the frame of the f...

Страница 14: ...2 74m 2 Conductor 14 Gauge IP Rated Power Data Pigtail Cable CONSTRUCTION PHYSICAL PERFORMANCE Dimensions LxWxH 23 42 x 3 94 x 4 13 in 595 x 100 x 105 mm Weight 4 85 lbs 2 2 kg ELECTRICAL Input Voltag...

Страница 15: ...15 DIMENSIONAL DRAWINGS Drawings not to scale...

Страница 16: ......

Отзывы: