TIMER

Interval

0~2500s

Start or pause 

device operation 

according to these 

values by pressing 

the Play/Start icon.

Duration

0~250s

Fan Speed

20%~100%

PRESET

Preset 1

See Preset Modes 

section

Preset 2
Preset 3
Preset 4
Preset 5

INFORMATION

State

Normal / Error

Slot 1

Null / MagFly / Wifi / MagRF

Slot 2

Null / MagFly / Wifi / MagRF

Last Control

LCD_auto / LCD_manual / DMX 

/ Wifi / MagRF / MagRemote / 

Error

Displays current 

source of device 

control

MagRemote 

State

Yes / No

Displays whether 

remote control is 

connected

Wifi Connect

Null / Phone / Route / No

Wifi connection 

source

Wifi IP

No / 0~255, 0~255, 0~255, 0~255

MagFly Ch

0-14

DMX Addr

1-512

DMX Mode

1-ch / 2-ch / 4-ch

Timer Fan Sp 20% - 100%
Timer Int

0-2500s

Timer Dur

0-250s

LCD Ver

V1.2

Sftwr Ver

V1.0

Содержание MAGMAFAN1

Страница 1: ...User Manual MAGMAFAN1 US SKU MSF013 UPC 810008261514 ITF 14 10810008261511...

Страница 2: ...ersons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent a...

Страница 3: ...y USA Only 5 Warranty Returns USA Only 6 Safety Guidelines 7 Maintenance Guidelines 9 Overview 10 Installation Instructions 11 Control Panel 13 System Menu 14 Preset Mode 16 DMX Channel Functions Valu...

Страница 4: ...without first contacting customer support Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Twist Lock Power Cable x1 CUSTOMER SUPPORT Contact MAGMA...

Страница 5: ...anual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magmatic Effects will replace defective pa...

Страница 6: ...pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of the probl...

Страница 7: ...the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VO...

Страница 8: ...ng DO NOT block any air ventilation slots All fan and air inlets must remain clean and free of dust and debris Allow approx 6 15cm between fixture and other devices or a wall for proper cooling When i...

Страница 9: ...ou need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check by an approved electrical...

Страница 10: ...ille x2 5 Optional Module Installation Point x2 6 Wired Remote Port 7 Breaker 8 Power In 9 DMX Out 10 Power Out 11 DMX In 12 Safety Cable Loop device shown with optional equipment installed actual equ...

Страница 11: ...e a professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the device s clamps cables and a...

Страница 12: ...Y CABLE of the appropriate rating to the safety cable loop SAFETY CABLE ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING THIS DEVICE IN A SUSPENDED EN VIRONMENT TO ENSURE THAT THE DEVICE WILL NOT FALL IN...

Страница 13: ...the UP and DOWN buttons to make adjustments Press the ENTER button to confirm your adjustments You may exit the main menu at any time without making any adjust ments by pressing the BACK EXIT button W...

Страница 14: ...Failed try again Wifi DMX Magfly On Off LCD Set Screen OFF Never 10s 40s 1min 2min 5min 10min 20min Display Flip 0 deg 180 deg MagFly Set MagFly Channel 0 14 MagFly On Off MagRF Learn Connected Freque...

Страница 15: ...ror Slot 1 Null MagFly Wifi MagRF Slot 2 Null MagFly Wifi MagRF Last Control LCD_auto LCD_manual DMX Wifi MagRF MagRemote Error Displays current source of device control MagRemote State Yes No Display...

Страница 16: ...nterval and fan speed for the selected preset mode will be displayed on the screen below the numerical buttons Press the PLAY button in the bottom right corner of the screen to operate the device acco...

Страница 17: ...ANNEL VALUES FUNCTION 1 CH 2 CH 4 CH 1 1 On Off 000 005 Off 006 255 On 1 Fan Speed 000 005 Off 006 255 20 100 2 2 Fan Speed 000 005 20 006 255 21 100 3 Duration 000 005 0s 006 255 1s 250s 4 Interval 0...

Страница 18: ...DIMENSIONAL DRAWINGS Drawings not to scale Device is shown with optional equipment actual equipment level of your device may vary 18...

Страница 19: ...ptional MAGRF Wireless and Wired Remotes CONNECTIONS Locking 5pin XLR Connector In Out IP65 Locking Power Connector In With Wired Digital Communication Network SIZE WEIGHT Length 15 55 in 395mm Width...

Страница 20: ......

Отзывы: