background image

SYSTEM MENU

PERSONALITY

(cont’d from 

prev page)

MagRF Learn

Frequency Match-

ing feature. 

Display will read 

“Connected” if 

connection at-

tempt succeeds 

within 20 sec-

onds. Otherwise, 

display will read 

“Connection 

Failed.”

When Magfly is not equipped, select-

ing this function causes “Optional 

Module Not Installed” to show on the 

screen.

Last State

Yes / No

When powered up, device 

adheres to last settings from 

before power was shut off

Default

Yes / No

Restore to factory settings

MANUAL

LED Off

Start or pause device operation 

according to these values by 

pressure the Play/Start icon.

Auto 1 - 4
Color 1 - 75 

(see Color 

Table)

Intensity

0 - 100%

TIMER

Duration

0 - 250 s

Start or pause device operation 

according to these values by 

pressure the Play/Start icon.

Interval

0 - 2500 s

LED Off
Auto 1 - 4
Color 1 - 75 

(see Color 

Table)

Intensity

0 - 100%

CONTINUED ON NEXT PAGE

14

Содержание 810008261545

Страница 1: ...User Manual JAVELIN US SKU RSJ150 UPC 810008261545 ...

Страница 2: ... unsafe insufficient and negligent assembly installation rigging and opera tion of this product DOCUMENT VERSION Due to additional product features and or enhancements an updated version of this document may be available online Please check www elationlighting com for the latest revision update of this manual before beginning installation and or programming MAGMATIC EFFECTS 6122 S Eastern Ave Los ...

Страница 3: ... Safety Guidelines 7 Overview 9 Installation 10 Operation 11 Control Panel 12 System Menu 13 DMX Channel Functions Values 17 LED Layout 18 Macros Table 19 Color List 20 Dimensional Drawings 21 Trouble Shooting Cleaning Maintenance Optional Accessories 22 Specifications 23 FCC Statement 24 ...

Страница 4: ...ash Please recycle whenever possible BOX CONTENTS Twist locking power cable CUSTOMER SUPPORT Contact MAGMATIC customer service for any product related service and support needs Also visit forums elationlighting com with questions comments or suggestions ELATION SERVICE USA Monday Friday 8 00am to 4 30pm PST 323 582 3322 Fax 323 832 9142 sales magmaticeffects com ELATION SERVICE EUROPE Monday Frida...

Страница 5: ...manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magmatic Effects will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Magmatic Effects under this warranty s...

Страница 6: ...t pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of the problem and the RMA number must be documented and included in the box Products returned for warranty service without an RMA number clearly marked on the outside of the package will be refused and returned...

Страница 7: ...RTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL VOID YOUR MANUFACTURER S WARRANTY DAMAGES RESULTING FROM MODIFICATIONS TO THIS DEVICE AND OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND OR REPAIRS DO NOT PLUG THIS UNIT INTO A DIMMER PACK DO NOT REMOVE THE COVER UNDER ANY CON...

Страница 8: ... from flames and flammable or explosive substances Never pour flammable liquids such as gas perfume etc into the fog machine Keep the device and fog fluid out of reach of children Use only under adult supervision Do not direct fog output in the direction of people or open flame Stay at least 20 inches 50cm from the output nozzle on the front of the unit Do not obstruct the output nozzle Do not ope...

Страница 9: ...1 Fog Outlet 2 LED Array 3 Wired Remote Port 4 DMX In 5 DMX Out 6 Power In 7 Breaker 8 Carry Handle 9 Touch Screen Display 10 Tank Fill Cap 11 Safety Cable Attachment 12 Tank Level Indicator OVERVIEW 9 ...

Страница 10: ... SAFETY CABLE WHENEVER INSTALLING THIS UNIT IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE DEVICE WILL NOT FALL IF THE CLAMPS FAIL CLAMP INSTALLATION This device features attachment points for two 2 omega brackets located on the device underside near the underside vents A safety cable rigging point is also included located beside the carry handle see the illustration below When mounting this unit t...

Страница 11: ...TION While the fog duration setting can be set as high as 250 seconds the individual bursts of continuous fog output will only occur for a maximum of 8 seconds For example when the user sets a duration of 250 seconds this does NOT mean that the device will be emitting fog continuously for the entire 250 second period Rather the device will produce a series of shorter fog bursts each lasting up to ...

Страница 12: ... the main menu will be displayed see Main Menu Screen below Press the main menu icon you would like to access Use the ENTER button to access sub menus and use the UP and DOWN buttons to make adjustments Press the ENTER button to confirm your adjustments You may exit to the main menu at any time without making any adjustments by pressing the BACK EXIT button CONTROL PANEL 12 ...

Страница 13: ... On Off Allows MagApp data to be con verted to DMX data and then sent out via DMX port and Magfly LCD Set Screen OFF Never 10s 40s 1 min 2 min 5 min 10 min 20 min Display Flip 0 deg 180 deg Magfly Set Magfly Channel 0 14 When Magfly is not equipped selecting this function causes Optional Module Not Installed to show on the screen Magfly ON OFF CONTINUED ON NEXT PAGE SYSTEM MENU 13 ...

Страница 14: ...creen Last State Yes No When powered up device adheres to last settings from before power was shut off Default Yes No Restore to factory settings MANUAL LED Off Start or pause device operation according to these values by pressure the Play Start icon Auto 1 4 Color 1 75 see Color Table Intensity 0 100 TIMER Duration 0 250 s Start or pause device operation according to these values by pressure the ...

Страница 15: ... Strobe LED Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF1 Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF2 Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF3 Style LED Off Auto 1 4 Color 1 75 see Color Table MagRF4 Style LED Off Auto 1 4 Color 1 75 see Color Table INFORMATION State Normal Error Operational status of unit Slot 1 Null Displays what type of module is connecte...

Страница 16: ...the type of the device that the MagApp has connected to Phone Route router No MagApp IP IP address set by user MagFly Ch 0 14 Current MagFly channel DMX Addr 1 512 Current DMX address of unit DMX Mode 1 4 12 Current DMX mode of unit Timer Int 0 2500 s Current timer interval setting Timer Dur 0 250 s Current timer duration setting Heating 0 100 Progress of fluid heating Heater State Normal Operatio...

Страница 17: ...oop 181 205 Fog burst lighting display loop 1s loop 206 230 Auto 2 231 255 Auto 1 2 2 000 255 Red1 0 to 100 4 3 000 255 Blue1 0 to 100 5 4 000 255 Amber1 0 to 100 5 000 255 Red2 0 to 100 3 6 000 255 Green2 0 to 100 7 000 255 Blue2 0 to 100 8 000 255 Amber2 0 to 100 9 000 255 Red3 0 to 100 10 000 255 Green3 0 to 100 3 6 11 Strobe 000 031 Off 032 095 Random slow to fast 096 159 Pulse Effect in seque...

Страница 18: ...LED LAYOUT for 12 Channel Mode ABBREVIATION LED ZONE NAME R1 Red 1 B1 Blue 1 A1 Amber 1 R2 Red 2 G2 Green 2 B2 Blue 2 A2 Amber 2 R3 Red 3 G3 Green 3 18 ...

Страница 19: ...5 026 Macro 11 085 086 Macro 41 145 146 Macro 71 027 028 Macro 12 087 088 Macro 42 147 148 Macro 72 029 030 Macro 13 089 090 Macro 43 149 150 Macro 73 031 032 Macro 14 091 092 Macro 44 151 152 Macro 74 033 034 Macro 15 093 094 Macro 45 153 154 Macro 75 035 036 Macro 16 095 096 Macro 46 037 038 Macro 17 097 098 Macro 47 039 040 Macro 18 099 100 Macro 48 041 042 Macro 19 101 102 Macro 49 043 044 Mac...

Страница 20: ...or 71 Color 10 Color 41 Color 72 Color 11 Color 42 Color 73 Color 12 Color 43 Color 74 Color 13 Color 44 Color 75 Color 14 Color 45 Color 15 Color 46 Color 16 Color 47 Color 17 Color 48 Color 18 Color 49 Color 19 Color 50 Color 20 Color 51 Color 21 Color 52 Color 22 Color 53 Color 23 Color 54 Color 24 Color 55 Color 25 Color 56 Color 26 Color 57 Color 27 Color 58 Color 28 Color 59 Color 29 Color 6...

Страница 21: ...DIMENSIONAL DRAWINGS Dimensions may not be drawn to scale 21 ...

Страница 22: ...ance CLEANING MAINTENANCE When storing your device be sure to store in a cool area Cover the device so that dust does not build up on the device When storing for long periods of time it is highly advisable to run the device at least once every 3 4 months Long periods of inactivity can severely shorten the life of your device Only run Magmatic s Atmosity fluid through your machine Never run plain w...

Страница 23: ...Fluid Level Detection Compact Light Weight Mobile Design CONTROL 4 DMX Channel Modes 1 4 7 12 Onboard LCD Touch Control Panel DMX 512 and RDM Protocol Support Optional MagFly Wireless DMX Transceiver Optional MagRF Wireless and Wired Remotes CONNECTIONS Locking 5pin XLR Connector In Out IP65 Locking Power Connector In With Wired Digital Communication Network SIZE WEIGHT Length 15 0 in 380mm Width ...

Страница 24: ...cordance with the included instructions may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the device off and on the user is encouraged to try to correct the interference by one or more of...

Страница 25: ...25 ...

Страница 26: ......

Отзывы: