4. INSTALLATION AND MOUNTING 

This type of equipment should be installed and mounted by qualified and experienced 
technicians.  

4.1 IMPORTANT SAFETY INSTRUCTIONS 

Please, follow these instructions while installing the cabinet: 
•Personnel responsible for moving and installing equipment must have flexible and non-slip work 
gloves, safety glasses, and safety shoes that must be used whenever necessary. 
 
•Follow the instructions in the "Installation" section of the current manual and additional 
guidelines, if applicable. 
 
•Do not walk on the equipment.  
 
•Do not install and use the equipment if it is damaged. 
At installing the device near a wall, respect the distance of not less than 60 mm.  

4.2 EQUIPMENT MOUNTING 

Thoroughly remove any polyethylene film protecting the components and parts of the display 
cabinet.  

If this manual contains a Chapter with installation Instructions, follow the sequence indicated for 
proper installation. 

Align the display case in a horizontal position by adjusting the leveling feet. 

Use only hand tools to fix screws when mounting glass components and parts. 

We recommend installing, if necessary, mechanical protection devices adapted to the equipment 
to prevent possible damage, for example, from the impact of a trolley, a polisher, a loader, etc. 

4.3 ADJUSTMENT OF THE FRONTAL GLASSES 

Adjustment of the frontal glasses should ensure minimal and sufficient clearance between them  
in 'lowered' and 'lifted' positions. A contact of glasses is unacceptable. 

4.4 POWER SUPPLY CONNECTION 

Make sure the voltage of the electric supply corresponds to the data specified on the nameplate 
of the device. Deviations in the electric supply circuit voltage should not exceed ±10% from those 
specified on the nameplate.  

The equipment does not have any protection from overvoltage, so it is recommended to check 
the safety level of the electric circuit to which the device will be connected to.  

The device has a terminal for connecting with a potential equalization connector when it is 
necessary to prevent the presence of voltage when touching between the grounding equipment 
and metal parts that may accidentally come into contact with current-carrying electrical wires. 
This terminal, marked with the corresponding symbol, is located in the electronics unit and is 
intended for connection to the ground circuit with a wire with a cross section of 2.5-6 mm2.  

Connect the equipment to the electrical network only at the end of installation. 

 

Содержание BERILL T

Страница 1: ...______________________________________________________________________________________________________________________________________________________________________ OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...ure to follow the recommendations and instructions contained in this manual Notice All dimensions in drawings are given in mm if not otherwise specified Illustrations may not fully correspond to the m...

Страница 3: ...f food products whose storage temperature corresponds to the temperature range of the display case 1 3 DEVELOPMENT AND STANDARDIZATION This equipment has been designed and manufactured in accordance w...

Страница 4: ...h as aerosol cans containing flammable mixtures inside this appliance ATTENTION it is strictly forbidden to turn on the display case without grounding and move the display case that is under voltage M...

Страница 5: ...00 Infrared lamps W 3 x 300 6 x 300 Lighting type LED Backlight power consumption W 18 36 Rated power consumption per day 1 Basic set of the cabinet light 12h kW h 21 4 42 8 Dimensions Overall dimensi...

Страница 6: ...hanical protection devices adapted to the equipment to prevent possible damage for example from the impact of a trolley a polisher a loader etc 4 3 ADJUSTMENT OF THE FRONTAL GLASSES Adjustment of the...

Страница 7: ...THE EDGE OF THE GLASS AND AS A RESULT DESTROY IT 5 2 TURNING ON THE DISPLAY CASE Turn on the display case only after carrying out all preparatory works fulfilled by qualified personnel To turn on the...

Страница 8: ...ENANCE Before cleaning or maintenance the equipment must be disconnected from the power supply to guarantee the absence of an electric current in the system Purpose of cleaning is to remove pathogenic...

Страница 9: ...EQUIPMENT S LIFE CYCLE At the end of a useful life of the equipment we recommend the following Make it unserviceable for example cut power cable Remove glass shutters or other elements which may be da...

Страница 10: ...9 Appendix A ELECTRIC WIRING DIAGRAM BERILL T 125...

Страница 11: ...10 Appendix B ELECTRIC WIRING DIAGRAM BERILL T 250...

Страница 12: ...menu folders until the FAn folder While on the folder label FAn press the set button the first folder parameter will appear on the controller display Use the Up and Down buttons to switch to the FSt p...

Страница 13: ...e will work with the newly set temperature value of the upper space Find below an example of a sequence of actions to change the value of the FSt parameter from 60 C to 80 C 5 seconds Turn off and tur...

Страница 14: ...RMS page labeled AL AFd Alarm differential 2 0 1 F Differential activation of the alarm signal HAL Higher ALarm Maximum alarm 90 0 1 F The value of the higher temperature limit DISPLAY page labeled di...

Страница 15: ...d and similar electrical appliances Safety Part 2 49 Particular requirements for commercial electric appliances for keeping food and crockery warm is in conformity with the Directives 2014 30 EU Elect...

Отзывы: