Magic-Pak MHP4 Series Скачать руководство пользователя страница 8

Page 8 of 17

507861-01

Issue 1927

Model Number

Filter Area 

(in

2

)

*MHP4-11-09* 

*MHP4-11-12*

265

3MHP4-11-18*

5MHP4-11-18*

310

7MHP4-11-18* 

10MHP4-11-18*

360

*MHP4-11-24*

400

*MHP4-11-30*

515

*MHP4-11-36*

600

Table 5. Minimum Required Surface Area for 

Disposable Filters

Condensate Drain

Provisions must be made to properly drain the indoor and 

outdoor drain pans of this appliance.

Indoor  drain  and  outdoor  drain  connection:  3/4”  NPT  to 

3/4” PVC fitting (schedule 40 minimum). Both drains must 

be trapped as shown in Figure 6. The drain line should 

pitch gradually downward at least 1” per 10’ of horizontal 

run to an open drain.

Figure 6. Condensate Drain Installation

If local codes require the use of metal condensate lines, 

do not thread metal fittings into the unit drain pans. Thread 

a PVC fitting into the unit drain pans and make the field 

connection to the PVC fitting. 

NOTE: 

MHP units are designed with a redundant drain 

system  to  handle  condensate  without  the  need  for  a 

secondary  or  emergency  drain  pan.  Should  the  indoor 

coil  condensate  drain  system  fail,  all  water  is  contained 

within the unit and the flow is directed into the unit base 

pan.  From  there  it  will  drain  into  the  condensate  riser. 

If  for  some  reason  the  water  cannot  drain  into  the  main 

condensate riser, all water is contained in the unit, and the 

design will allow drainage out through the wall sleeve and 

louver assembly to the outside of the building.

Use  thread  sealant  on  the  threaded  fittings.  Install 

threaded fittings by hand only. 

Do not over torque the 

fittings.

Do  not  thread  metal  condensate  fittings  to  unit  drain 

pans.

 CAUTION

Outdoor Ventilation Air

Units  are  fitted  with  a  panel  that  seals  the  return  air 

compartment at the outdoor air duct. If introduction of 

outdoor air is desired, installers can replace the factory-

installed panel with the provided auxiliary panel by removing 

screws holding both the factory and auxiliary panels, and 

then replacing with the auxiliary panel and screw. 

NOTE: 

If outdoor ventilation air is introduced, the quantity 

of air and conditions of this air must be accounted for in the 

load calculations for the unit installation.

The auxiliary panel includes nine knockouts to configure 

air  flow  to  installation  requirements.  Use  Table  6  and 

Figure 7 to determine which knockouts to remove from the 

auxiliary panel in order to achieve the desired air flow. Use 

a flat head screw driver to remove the knockouts. Set the 

factory-installed panel aside for possible future changes.

Outdoor Ventilation Air 

(CFM)

*MHP4-1

1-09*

*MHP4-1

1-12*

*MHP4-1

1-18*

*MHP4-1

1-24*

*MHP4-1

1-30*

*MHP4-1

1-36*

Nominal 

Indoor Airflow

350

475

600

800

1025 1200

Number of Openings

#1 Only

6

11

13

18

20

23

#1 and #2

10

17

21

24

28

31

#1 thru #3

17

22

26

32

36

41

#1 thru #4

23

28

35

41

45

49

#1 thru #5

31

34

42

50

55

60

#1 thru #6

35

41

49

57

66

72

#1 thru #7

41

49

56

68

80

86

#1 thru #8

46

56

64

78

88

98

#1 thru #9

50

60

73

90

100

112

Table 6.  

Содержание MHP4 Series

Страница 1: ...any state or provincial laws or local ordinances Local authorities having jurisdiction should be consulted before installation is made Such applicable regulations or requirements take precedence over...

Страница 2: ...confirm specifications are as ordered Limitations The unit should be installed in accordance with all national and local safety codes Limitations of the unit and appropriate accessories must also be...

Страница 3: ...g a door or access panel opposite the front of the unit is the preferred method of providing access The door or access panel must be at least 30 wide centered on the unit and as tall as the unit IMPOR...

Страница 4: ...ille Installation Refer to installation instructions included with the wall sleeve kit and the louver grille kit along with Figure 2 for guidance in assembling and installing the wall sleeve and louve...

Страница 5: ...on to top and bottom corners of unit to sleeve seal Caulk if needed Ductwork Ductwork should be designed and sized according to the methods in Manual Q of the Air Conditioning Contractors of America A...

Страница 6: ...W TAP 4 AUX HEAT 615 93 590 97 555 101 N A N A N A N A TAP 5 AUX HEAT 715 127 685 134 655 140 630 146 600 151 5 kW TAP 4 AUX HEAT 665 110 635 114 605 118 N A N A N A N A TAP 5 AUX HEAT 750 148 725 154...

Страница 7: ...eed for Cooling operation Blower speed must be field adjusted to Speed Tap 3 for higher duct static applications As shipped speed for Heating operation Blower speed must be field adjusted to Speed Tap...

Страница 8: ...wall sleeve and louver assembly to the outside of the building Use thread sealant on the threaded fittings Install threaded fittings by hand only Do not over torque the fittings Do not thread metal c...

Страница 9: ...inlets to flue gas terminals Improper installation could result in personal injury or death WARNING Figure 7 Auxiliary and Factory Panel for Outdoor Air Duct Factory panel Outdoor Air Duct Auxillary...

Страница 10: ...ort during defrost The unit will remain in defrost until the defrost sensor has determined that the frost has been removed from the coil or a 14 minute time period has elapsed The defrost control is a...

Страница 11: ...cleaner Wash filter in soap or detergent water and replace after filter is dry It is not necessary to oil the filter after washing Motors The indoor and outdoor fan motors are permanently lubricated...

Страница 12: ...1P Extruded Aluminum Louver Kit 33 Height ALVRAL 2 Extruded Aluminum Louver Kit Custom Color 33 Height ALVRAL 2P Extruded Aluminum Louver Kit 45 Height ALVRAL 3 Extruded Aluminum Louver Kit Custom Co...

Страница 13: ...Louver ASLEEVE8 2 8 32 3 4 16 16 5 8 32 7 8 for 45 Louver ASLEEVE8 5 8 45 16 16 5 8 45 1 8 10 Wall Sleeve Kit for 29 Louver ASLEEVE10 1 10 29 16 16 5 8 29 1 8 for 33 Louver ASLEEVE10 2 10 32 3 4 16 16...

Страница 14: ...Page 14 of 17 507861 01 Issue 1927 Figure 11 Connection Diagram MHP With Single Circuit Without Hard Start 538014 01 Wiring Diagrams...

Страница 15: ...507861 01 Issue 1927 Page 15 of 17 Figure 12 Connection Diagram MHP With Dual Circuits Without Hard Start 538014 02...

Страница 16: ...Page 16 of 17 507861 01 Issue 1927 Figure 13 Connection Diagram MHP With Single Circuit and Hard Start Enabled 538051 01...

Страница 17: ...507861 01 Issue 1927 Page 17 of 17 Figure 14 Connection Diagram MHP With Dual Circuit and Hard Start Enabled 538051 02...

Отзывы: