Magic-Pak MHP4 Series Скачать руководство пользователя страница 1

507861-01

Issue 1927

Page 1 of 17

Save these instructions for future reference

INSTALLATION AND MAINTENANCE INSTRUCTIONS

MHP4 Series

Self-Contained Heat Pump

Manufactured By

Allied Air Enterprises LLC

A Lennox International Inc. Company

215 Metropolitan Drive

West Columbia, SC 29170

This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in 

manuals, be alert to the potential for personal injury or death.

Improper installation, adjustment, alteration, service, or 

maintenance can cause injury or property damage. Refer 

to this manual. For assistance or additional information, 

consult a qualified installer or service agency.

 WARNING

Table of Contents

Installation ...................................................................1

Operation .....................................................................9

Maintenance ..............................................................11

Accessories ...............................................................12

Wiring Diagrams ........................................................14

The installation of this appliance must conform to the requirements of the National Fire Protection Association; the National 

Electrical Code, ANSI/NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code Part 1, CSA 22.1 

(latest edition) in Canada; and any state or provincial laws or local ordinances. Local authorities having jurisdiction should 

be consulted before installation is made. Such applicable regulations or requirements take precedence over the general 

instructions in this manual.

 CAUTION

 

(P) 507861-01

*P507861-01*

Installation

These units are not approved for mobile home 

applications. Such use could result in property damage, 

personal injury, or death.

 WARNING

General

These instructions explain the recommended method of 

installation of the MHP4 electric cooling unit and associated 

electrical wiring.

This unit is designed and approved for use as a self-

contained air-to-air air conditioning system with optional 

CLIMATE GUARD™ coated coils.

These instructions, and any instructions packaged with 

mating components and/or accessories, should be carefully 

read prior to beginning installation. Note particularly any 

CAUTIONS

 or 

WARNINGS

 in these instructions and all 

labels on the units.

These instructions are intended as a general guide only, 

for use by qualified personnel and do not supersede any 

national or local codes in any way. Compliance with all local, 

state, provincial, or national codes pertaining to this type of 

equipment should be determined prior to installation.

Содержание MHP4 Series

Страница 1: ...any state or provincial laws or local ordinances Local authorities having jurisdiction should be consulted before installation is made Such applicable regulations or requirements take precedence over...

Страница 2: ...confirm specifications are as ordered Limitations The unit should be installed in accordance with all national and local safety codes Limitations of the unit and appropriate accessories must also be...

Страница 3: ...g a door or access panel opposite the front of the unit is the preferred method of providing access The door or access panel must be at least 30 wide centered on the unit and as tall as the unit IMPOR...

Страница 4: ...ille Installation Refer to installation instructions included with the wall sleeve kit and the louver grille kit along with Figure 2 for guidance in assembling and installing the wall sleeve and louve...

Страница 5: ...on to top and bottom corners of unit to sleeve seal Caulk if needed Ductwork Ductwork should be designed and sized according to the methods in Manual Q of the Air Conditioning Contractors of America A...

Страница 6: ...W TAP 4 AUX HEAT 615 93 590 97 555 101 N A N A N A N A TAP 5 AUX HEAT 715 127 685 134 655 140 630 146 600 151 5 kW TAP 4 AUX HEAT 665 110 635 114 605 118 N A N A N A N A TAP 5 AUX HEAT 750 148 725 154...

Страница 7: ...eed for Cooling operation Blower speed must be field adjusted to Speed Tap 3 for higher duct static applications As shipped speed for Heating operation Blower speed must be field adjusted to Speed Tap...

Страница 8: ...wall sleeve and louver assembly to the outside of the building Use thread sealant on the threaded fittings Install threaded fittings by hand only Do not over torque the fittings Do not thread metal c...

Страница 9: ...inlets to flue gas terminals Improper installation could result in personal injury or death WARNING Figure 7 Auxiliary and Factory Panel for Outdoor Air Duct Factory panel Outdoor Air Duct Auxillary...

Страница 10: ...ort during defrost The unit will remain in defrost until the defrost sensor has determined that the frost has been removed from the coil or a 14 minute time period has elapsed The defrost control is a...

Страница 11: ...cleaner Wash filter in soap or detergent water and replace after filter is dry It is not necessary to oil the filter after washing Motors The indoor and outdoor fan motors are permanently lubricated...

Страница 12: ...1P Extruded Aluminum Louver Kit 33 Height ALVRAL 2 Extruded Aluminum Louver Kit Custom Color 33 Height ALVRAL 2P Extruded Aluminum Louver Kit 45 Height ALVRAL 3 Extruded Aluminum Louver Kit Custom Co...

Страница 13: ...Louver ASLEEVE8 2 8 32 3 4 16 16 5 8 32 7 8 for 45 Louver ASLEEVE8 5 8 45 16 16 5 8 45 1 8 10 Wall Sleeve Kit for 29 Louver ASLEEVE10 1 10 29 16 16 5 8 29 1 8 for 33 Louver ASLEEVE10 2 10 32 3 4 16 16...

Страница 14: ...Page 14 of 17 507861 01 Issue 1927 Figure 11 Connection Diagram MHP With Single Circuit Without Hard Start 538014 01 Wiring Diagrams...

Страница 15: ...507861 01 Issue 1927 Page 15 of 17 Figure 12 Connection Diagram MHP With Dual Circuits Without Hard Start 538014 02...

Страница 16: ...Page 16 of 17 507861 01 Issue 1927 Figure 13 Connection Diagram MHP With Single Circuit and Hard Start Enabled 538051 01...

Страница 17: ...507861 01 Issue 1927 Page 17 of 17 Figure 14 Connection Diagram MHP With Dual Circuit and Hard Start Enabled 538051 02...

Отзывы: