Junction Box

Use Screws to secure 

Junction box

No Gap

Remove Knock-out over opening, pull unit wiring leads through

Figure 5. 

Figure 6. 

Thermostat

Install the thermostat according to the directions furnished 

with it. The thermostat must be located on an inside wall 

where it will not be affected by drafts, sunlight, or any other 

heat producing appliances. Connect the thermostat wires 

to the low voltage leads on top of the unit following the 

wiring diagram attached to the unit. The heat anticipator 

setting is 0.50 amp.

NOTE: 

For  HWC8*30  models,  a  two-stage  thermostat  is 

recommended for reaching highest efficiency and full use 

of two-stage compressor. 

Air Filter

All  indoor  return  air  must  be  filtered.  A  permanent-type 

filter is furnished with the unit, located directly behind the 

access panel. Removing the panel permits access to the 

filter. See Figure 3.

If an installation is made in which it is more desirable to 

mount the filter exterior to the unit, in the return duct work 

or elsewhere, the permanent filter can be used or replaced 

with a disposable filter. If a disposable filter is used, refer 

to  the  information  provided  in  Table  1  when  sizing  the 

disposable filter.

Model Number

Filter Area 

(sq. in.)

HWC8*12

300

HWC8*18

480

HWC8*24

480

HWC8*30

480

Table 1. Minimum Required Surface Area for 

Disposable Filters

Supply and Return Duct(s)

Provide duct(s) sized sufficiently to handle the larger of the 

air volumes for heating or cooling provided by this model.

Connect the supply duct to the top of the unit using canvas 

connections or other flexible connections to prevent noise 

transmission into the duct system.

To connect the return duct to the system, use a straight 

piece of duct 22” wide by 6” deep. Insert the duct into the 

return  opening  in  the  bottom  of  the  unit  and  flange  the 

duct over the existing flanges around the opening inside 

the unit. Make sure that all sides of the duct are flanged 

over to permit removal of the cooling chassis if required. 

Use a flexible connection to attach the remainder of the 

return duct. The return duct should be sealed to the unit 

casing and must terminate outside the space containing 

the furnace.

Содержание HWC8 V Series

Страница 1: ...ombustible materials near the furnace or warm air ducts The material may ignite by spontaneous combustion creating a fire hazard WARNING These units are not approved for mobile home applications Such...

Страница 2: ...03 Issue 2127 22 27 7 8 29 7 16 13 3 8 43 3 16 16 1 6 1 8 1 Supply Return Low Voltage Supply Line Voltage Box 1 3 4 8 2 3 4 1 1 2 2 7 8 18 1 4 2 2 1 2 Gas Inlet Condensate Drain HWC9 Only Return Supp...

Страница 3: ...ile or other combustible material other than wood flooring The grille side of the unit may be flush with or extend beyond the face of the exterior wall but should not be recessed more than 2 from the...

Страница 4: ...When properly nested the angle on top of the unit should line up with the top flange of the sleeve and should almost touch Fasten the unit to the sleeve with five screws furnished with the sleeve The...

Страница 5: ...could cause an unsafe condition 3 Insofar as is practical close all building doors and windows between the space in which the appliances remaining connected to the common venting system are located an...

Страница 6: ...losing the individual manual shutoff valve during any pressure testing of gas supply piping system at test pressures equal to or less than 1 2 psig or 14 W C If the piping system is to be tested at pr...

Страница 7: ...the unit Refer to the rating plate located on the unit for proper fuse or breaker size Make sure the unit is electrically grounded in accordance with local codes or in the absence of local codes with...

Страница 8: ...in the return duct work or elsewhere the permanent filter can be used or replaced with a disposable filter If a disposable filter is used refer to the information provided in Table 1 when sizing the...

Страница 9: ...e checked to see that none of the wiring is loose or missing Cooling chassis is charged with R410A refrigerant Blower The unit contains a direct drive multispeed blower The proper speeds have been pre...

Страница 10: ...6012P18A 45 75 60 TAP 1 HEAT 208 or 230 630 71 600 N A 570 N A 550 N A TAP 2 HEAT 208 or 230 770 58 740 60 715 62 690 64 TAP 3 HEAT 208 or 230 885 50 855 52 830 54 810 55 TAP 4 COOL 208 or 230 560 540...

Страница 11: ...ustment Screw Under Cap Gas Manifold Pressure Test Tap Model Rise Range F Mid Rise F Indoor Blower Speed Unit Voltage V 0 1 w c 0 2 w c 0 3 w c 0 4 w c SCFM Temp Rise F SCFM Temp Rise F SCFM Temp Rise...

Страница 12: ...ee times Should the burners fail to ignite within the three trials for ignition the ignition control will lock out for 1 hour before beginning another ignition cycle To reset the control turn the ther...

Страница 13: ...osen these screws to remove control board mounting bracket Ignition Control Board Remove these screws to remove Burner Assembly Igniter Combustion Inducer Gas Valve Primary Limit Mounted to Vest panel...

Страница 14: ...Verify proper operation after servicing WARNING Refer to Figure 8 for heating compartment component layout It is recommended that the furnace be inspected annually by a qualified service person Burner...

Страница 15: ...ew and pull the igniter out of the burner assembly 4 For reassembly follow the above steps in reverse order Rollout Switch If for any reason the heat exchanger becomes blocked the temperature sensitiv...

Страница 16: ...from the flue collector box end 6 Brush out the inside of the flue collector box 7 Brush out the inside of the flue tube extension 8 If soot buildup is excessive clean the combustion inducer wheel an...

Страница 17: ...507388 03 Issue 2127 Page 17 of 19 Figure 10 Wiring Diagram HWC 12 18 Wiring Diagrams...

Страница 18: ...Page 18 of 19 507388 03 Issue 2127 Figure 11 Wiring Diagram HWC 24...

Страница 19: ...507388 03 Issue 2127 Page 19 of 19 Figure 12 Wiring Diagram HWC 30...

Отзывы: