![MAGIC FX SMOKEBUBBLE BLASTER MFX1603 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/magic-fx/smokebubble-blaster-mfx1603/smokebubble-blaster-mfx1603_user-and-installation-manual_3452643009.webp)
10 MAGICFX® SMOKEBUBBLE BLASTER
—
User and Installation Manual
1.6 DMX CONTROL
When connected to DMX and with Manual mode OFF the MAGICFX
®
SMOKEBUBBLE BLASTER is
controlled with 1 safety address and 4 operational addresses:
DMX Address
Address range
Safety address
1 - 512
Start address (Bubble setting)
1 - 512
Start a 1 (Smoke setting)
1 - 512
Start a 2 (Fan speed)
1 - 512
Start a 3 (Go trigger)
1 - 512
DMX addresses
The safety address cannot be the same as (one of) the operational address(es). Operating of
these addresses results in the following:
DMX Address
DMX Value (decimal) Result
Safety address
0
99
Device disabled
100
155
Device enabled
156
255
Device disabled
Start address
(Bubble setting)
0
127
50% bubble capacity
128
255
100% bubble capacity
Start a 1
(Smoke setting)
0
85
No smoke
86
170
50% of bubbles contain smoke
171
255
100% of bubbles contain smoke
Start a 2
(Fan speed)
0
9
Fan OFF
10
255
Minimal speed -> Full speed
Start a 3
(Go trigger)
0
199
Effect OFF
200
255
Effect ON
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same safety address for all
machines.
CAUTION
Always plug in a DMX Terminator into the DMX output of the final unit in the
control sequence. Using a DMX Terminator improves signal reliability.