Magewell Ultra Encode Скачать руководство пользователя страница 34

NDI HX

Name:

 specify a name for current task to facilitate server management,

which will be displayed in server list.

Source Video

Group name

Specify the 

Group name

 which the source belongs to. It is case-

insensitive, and should be a combination of A to Z, a to z, 0 to 9 and
special characters like _-. Multiple groups are supported, which should
be comma-separated.
By default, it is public.

Source name

By default, it is 

#serial-no#

, serial number.

UDP Unicast

 indicates that the encoder sends a UDP stream directly to the

receiver. It is used where lower latency matters. And multiple simultaneous
streams will work independently for multiple receivers.

UDP Multicast

 indicates that the encoder sends the UDP stream to a

multicast group. It is used for one-to-many broadcast for lower CPU
utilization. Parameters in a multicast configuration include:

Multicast IP

 ranges from 224.0.0.0 to 239.255.255.255.

Subnet Mask

 can be legitimate value ranging from 255.0.0.0 to

255.255.255.0.

Time To Live

 ranges from 1 to 255. The default value is 4.

Discovery Server:

 turn on the switch to auto-detect a source sender in

different network segment and ping the sender. And the 

Server IP

 should

be the IP address of the server running discovery server software. By default,

34

Содержание Ultra Encode

Страница 1: ......

Страница 2: ...ent 12 Interfaces Indicators 15 Get Started With Ultra Encode 15 Access Web UI 16 Initialization 17 Web UI Configuration 17 Access the Web UI 17 Web UI Configuration 17 Access the Web UI 18 Sign In Ou...

Страница 3: ...y Encoder converts input signal to a user defined format using H 264 H 265 video encoders and AAC audio encoder It can push multiple streams to RTSP RTMP RTMPS SRT Caller SRT Listener NDI HX2 HLS push...

Страница 4: ...or Streaming Server provides live stream server configuration General provides general settings of your device Encoding Parameters provides wizards to configure encoding profile Network provides netwo...

Страница 5: ...ncode setup Part 2 YouTube setup Part 1 Ultra Encode Setup 1 Find Ultra Encode 1 Connect the encoder to a LAN and power it up 2 Connect input signal 3 Access Web UI i In Windows 10 open a File Explore...

Страница 6: ...Find your Device Sign In 6...

Страница 7: ...ession 1 In the left control pane go to Streaming Server tab Click Add Server and choose 2 Go to YouTube https www google com device and paste the code prompted 3 Follow the page instructions to log i...

Страница 8: ...an simply save the server with default parameters for streaming 5 Go back to the Streaming Server tab and turn on the switch before YouTube icon to start the streaming session Now the encoder is ready...

Страница 9: ...Part 2 YouTube Setup Create a live stream task in YouTube Studio to go live and specify the Title Category Privacy etc 9...

Страница 10: ...do not try to fix it by yourself Contact a qualified service technician or your retailer for help Before using the product make sure all cables are correctly connected and the power cables are not da...

Страница 11: ...is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by turning the de...

Страница 12: ...Interfaces Indicators Ultra Encode HDMI Figure 1 Ultra Encode HDMI Plug included Wi Fi antenna when you want to connect to a wireless network 12...

Страница 13: ...Ultra Encode SDI Figure 2 Ultra Encode SDI Plug included Wi Fi antenna when you want to connect to a wireless network 13...

Страница 14: ...one streaming address Breathing none of the live sessions is enabled On Ethernet connected Off Ethernet unconnected On Wi Fi connected Off Wi Fi unconnected All but PWR indicator lights flash once sim...

Страница 15: ...device in Network Other Devices ii Double click the device icon open the sign page of Web GUI Via device Wi Fi AP IP Address 192 168 48 1 i In your smartphone pad laptop turn on WLAN search for and jo...

Страница 16: ...lization and set a new device name We recommend that the distance between the Web UI and the encoder should be within 10m ii In your web browser enter 192 168 48 1 to open the Web UI The default admin...

Страница 17: ...e Explorer in your PC then locate your device in Network Other Devices ii Double click the device icon to open the sign page of Web GUI Via device Wi Fi AP IP Address 192 168 48 1 i In your smartphone...

Страница 18: ...nter your account and password in the SIGN IN page 2 Sign Out click the drop list icon behind the logging in username at the top right of the Web UI and select Sign out We recommend that the distance...

Страница 19: ...al volume and color HDMI SDI IN adjust input signal volume LINE IN adjust the audio connected to the LINE IN LINE OUT adjust the LINE OUT audio which remixes audio embedded in input signal and LINE IN...

Страница 20: ...sing on the target video platform Brightness range from 100 to 100 the default value is 0 Contrast range from 50 to 200 the default value is 100 Saturation range from 0 to 200 the default value is 100...

Страница 21: ...r device Hardware version hardware version of your unit Firmware version current firmware version that is installed in your unit You can update the firmware via the System Firmware tab Gives you an ov...

Страница 22: ...ube Facebook Twitch as well as self defined servers Click Edit to modify the parameters of the stream Click Delete to remove the source from the list Turn on off the switch to start stop streaming Cli...

Страница 23: ...1 session of HLS push RTSP or NDI HX NDI HX2 Total bitrates for different network connection types 24Mbps for all streams is recommended for a wired network connection 16Mbps for all streams is recomm...

Страница 24: ...Wi Fi The device scans for the available network according to the connection priority and connect to it for streaming If the current network is disconnected the unit automatically re scans according t...

Страница 25: ...prime network for streaming By default the network connection priority is Mobile Broadband Ethernet Wi Fi The device scans for the available network according to the connection priority and connect t...

Страница 26: ...am key will be displayed on the WebUI v Write a description Title and Video Game tag vi Go live now or schedule your live session 3 Choose the prime network for streaming By default the network connec...

Страница 27: ...ice and log in Your avatar will be displayed after a successful logging in 3 Choose the prime network for streaming priority and connect to it for streaming If the current network is disconnected the...

Страница 28: ...stream and enter title description and privacy Then a new live event would be added to your logging in account automatically And you can stream to YouTube using streamer without clicking on go live i...

Страница 29: ...s The part live cannot be omitted Stream key enter the stream key obtained from the live stream platform If none leave it empty Authentication turn on if your live streaming service provider requires...

Страница 30: ...o push main stream Specify parameters in Encoding Parameters tab Main key specify key for main stream The main key should be different from sub key Sub stream turn on to push sub stream Specify parame...

Страница 31: ...35 Connect timeout specify SRT connection timeout in milliseconds which ranges from 1000 to 30000ms The default value is 3000 Retry duration specify retry duration when SRT SRT connection timeout in m...

Страница 32: ...ode stream is recommended to below 24 Mbps below 16 Mbps via wireless network Name specify a name for current task to facilitate server management which will be displayed in server list Stream choose...

Страница 33: ...or stream data security Options are AES 128 192 256 Passphrase specify stream key of 10 to 79 characters which is the same as the SRT caller Save save current configuration The encoder can stream up t...

Страница 34: ...is used where lower latency matters And multiple simultaneous streams will work independently for multiple receivers UDP Multicast indicates that the encoder sends the UDP stream to a multicast group...

Страница 35: ...I channel which is automatically obtained after you select the backup NDI source Receiver Control turn on Web control to enable you to open the Web UI by clicking the gear icon in the NDI Studio Monit...

Страница 36: ...ream should be different Sub stream switch it on when you want to encode sub stream Modify the stream profile in Encoding Parameters tab Sub key set key for sub stream The sub key should be different...

Страница 37: ...ble network according to the connection priority and connect to it for streaming If the current network is disconnected the unit automatically re scans according to the priority By default the network...

Страница 38: ...ch size up to 1920x1080 512KB You can upload 2 more JPEG photos The device provided 2 pictures can not be deleted By default the switch is on General Device Name range from 1 to 32 characters includin...

Страница 39: ...the box to select other options including Full range 0 255 Limited range 16 235 Color format check the box to select other options including YUV BT 601 YUV BT 709 Quantization check the box to select...

Страница 40: ...ed to Cloud management Cloud status Online or Offline Online indicates that the communication between device and Cloud platform goes well On the other hand Offline indicates the communication is inter...

Страница 41: ...00ms To match up the audio and video tracks set a positive value to delay the start of the audio track or set a negative value to reduce the delay We recommend that you start your live after this conf...

Страница 42: ...the world time servers depending on the timezone you set Otherwise you can set time manually NTP server 1 the default server is 0 pool ntp org NTP server 2 the default server is 1 pool ntp org Reset...

Страница 43: ...264 encoder the profiles can be High Main profile Baseline For H 265 HEVC it can be Main profile Quantization range options are Full range 0 255 Limited range 16 235 Keyframe interval options are 1 2...

Страница 44: ...ng profile sub stream uses H 264 encoder The profiles can be High profile Main profile and Baseline Quantization range options are Full range 0 255 Limited range 16 235 Keyframe interval options are 1...

Страница 45: ...Set Audio AAC all audio streams will be affected by modifying the AAC bitrate It ranges from 16 to 256 Kbps and the default value is 128 Kbps 45...

Страница 46: ...the encoder will smartly select to send the EDID to the video source device to ensure both the encoder and the loop through device can obtain the signal they support Keep last Keep the last EDID valu...

Страница 47: ...f Add Audio is enabled the device will communicate with the video source device forcing it to output audio Limited pixel clock If enabled when the pixel resolution of the loop through device is beyond...

Страница 48: ...ng OUTPUT EDID OUTPUT EDID shows the EDID of the connected loop through device NOTE This section is available for HDMI products Export Click and set the file name to export the current EDID as a bin f...

Страница 49: ...ormation including Ethernet Wi Fi and AP can be set in the Network tab Set IP address manually turn on the switch to modify current network setting or when being connected to a non DHCP network IP add...

Страница 50: ...IP address WLAN IP address Subnet mask WLAN subnet mask Network gateway WLAN gateway DNS WLAN DNS server IP address Set IP address manually turn on the switch to modify current network setting or whe...

Страница 51: ...efault it is named after the device serial number IP address fixed as 192 168 48 1 Subnet mask fixed as 255 255 255 0 Change password AP password the default AP password is the last 8 number of the se...

Страница 52: ...y 3 Click Update button to download and install the new version file if any Do not disconnect from the power source or perform any operation while updating the firmware as this could damage your gear...

Страница 53: ...atically verify the update file and upload the file after the file verification is passed 2 Click Update to download and install the new version file Then the device will reboot to complete the update...

Страница 54: ...r password 5 Click OK You can add up to 15 general users 6 To delete a user Click Delete in the username card When prompted click Yes User Admin Administrator is allowed to perform the following tasks...

Страница 55: ...min tab with admin account Modify current logged in user password 1 Log in Web UI 2 Click the drop list icon beside your avatar icon and click Change password 3 In the pop up window type in your old p...

Страница 56: ...ator account 2 Go to User Admin tab then you can change any user s password 3 Click Set password 4 In the pop up window type in and confirm your password The password is a string of 1 to 32 characters...

Страница 57: ...Click Export to generate a html file 3 When prompted click Export About Obtain basic data for device maintenance in About tab Device name device name which can be modified in the General Device name...

Страница 58: ...ve stream server to use the main stream and the other to use the sub stream Yes You can select the main stream or sub stream for each session FAQ Allow simultaneous sessions over the same streaming pr...

Страница 59: ...figure Hold the paperclip in place until all indicators but power flash twice then remove the paper clip Be cautious that resetting would lose all your configuration data Forgot a general user s passw...

Страница 60: ...lease visit the following Technical Support Ticket System If you have any questions using Magewell products or need technical assistance please submit and track your inquiries by clicking here Support...

Страница 61: ...if the product is DOA Magewell will be responsible for the shipping cost 3 If some components need to be replaced Magewell will decide to repair renovate or replace the components by itself Magewell m...

Страница 62: ...placed product assumes 1 the remaining term of the Warranty of the replaced unit or faulty unit 2 ninety 90 days from the date of replacement or repair whichever provides longer coverage for you The e...

Страница 63: ...ut this Document This document is for reference only Please refer to the actual product for more details The user shall undertake any losses resulting from violation of guidance in the document In cas...