CHAPTER 4: Troubleshooting
ial communication doesn’t work correctly.
the serial devices connected properly? Are the serial
rameters correct for source/destination devices?
the serial cables terminated correctly? If a null-modem
ble is used, it must be placed at the receiver end.
en using RS-232 transmitters or receivers in daisy chains,
t5 switches, Cat5 distribution amps, or multi-output
nsmitters, the serial signal is a unidirectionally broadcast
ode only. In this mode, all other MultiView™ CAT5 Video
stem devices must be the simplex serial type.
e last device in a T4 transmitter or daisy chain configuration
st be a receiver unit with a terminated serial board.
e Appendix C for Serial board settings.
/SAP units have a fixed baud rate of 9600 bps and use 3 wire
X,RX,GND) signals only.
en shift” or “green washout” on multimedia signals.
standard video/serial model is designed to function with DC
led signals in which the black level is referenced to 0 volts.
ly all VGA cards function this way.
e media servers, however, provide AC coupled signals and
cause a green color shift in the video. This is a result of the
clamping on the red and blue channels of the video/serial
el.
ive-component (RGB/H&V) AC coupled video, the
View CAT5 XRTx Universal transmitter has been designed
full DC restoration capability. This problem is easily solved
simple switch setting in the XRTx Transmitter. Please refer to
XRTx Transmitter user manual.
s on Daisy Chaining:
n daisy chaining, the maximum cable distance is not increased
nd the rated distance of the receiver used. For example, an
00 can only daisy chain within 600 ft of the transmitter.
possible to daisy chain out of a short range receiver into a longer
e receiver to increase the range. For example, over 600 ft an
00 can be daisy chained into an AK1200 which allows for daisy
ning to 1,200 ft.
If using L/R summed audio, simplex serial, or SPDIF units a
maximum of 12 units may be daisy changed within the rated
cable length of the receiver.
When using SA units, a maximum of 4 units may be daisy
chained within the rated cable length of the receiver.
When using SAP units, a maximum of 12 units may be daisy
chained within the rated cable length of the receiver if using
standard cat5/6 or a maximum of 8 units may be daisy chained
within the rated cable length of the receiver if using skew-free
cable