2.1 Overview 

 

Magenta’s MultiView™ CAT5 Video System MultiView series extends VGA and audio 
signals over ordinary Category 5 cable.  
 
This manual covers the Magenta MultiView™ 500A CAT5 Video System Series 
Receiver with audio and the MultiView 500S receiver with RS232 serial support. 
 
For information on the respective transmitter unit, please refer to the appropriate 
manual included with the transmitter. 

 
 
 
 
 
 
 
 
 
 
2.2 Equipment You May Also Need 

 

1/8” (3.5mm) Audio cable with RCA jacks. 

1/8” (3.5mm) serial cable with DB9 connector. 

Video cable with HD15 connectors 

CAT5 cable 

 

2.3 Compatible Cabling 

Magenta  Research products are compatible with Cat5/5e/6 data cabling as well as skew free 
CAT5/5e cabling manufactured for video applications. Note that some skew free Cat5 is specific to 
a particular vendor and is not compatible with our products. Please ensure any skew free CAT5 
cable is non-proprietary prior to purchase/installation. 
CAT6 cable, due to the manufacture method, can exhibit much greater skew than standard 
CAT5/5e and may require skew compensation beyond what the standard product offers. Please 
contact Magenta Research for assistance. 
CAT5/5e/6 cabling for the Magenta MultiView™ Series  must be pinned to the TIA-EIA T568B 
wiring specification (see appendix A)  We also highly recommend that all CAT5 cables be pre-
terminated and tested. Cables terminated on-site or in an existing infrastructure should be tested 
before use to ensure compliance with the TIA-EIA T568B specification. Using incorrectly 
terminated CAT5 cables can damage the Magenta MultiView™ Series. 
 
The Cat5/5e/6 cable should be suitably rated Listed cable ( DUZX ) communication cables, TYPE 
CMP, CMR, CMG or CM as designated in the NEC. Cables are to be installed in accordance with 
the NEC and local building and electrical codes. This is the responsibility of the end user/installer 
of this product.

 

 

WARNING 

This equipment is not intended for, nor does it support, 
distribution through an Ethernet network. Do not connect these 
devices to any sort of networking or telecommunications 
equipment! 
Use only Magenta Research LTD  approved MultiView power 
adapters. Failure to do so, may damage this device and will void 
warranty. 

Содержание MultiView 500A

Страница 1: ...MultiView 500A 500S Receiver Quick Reference Setup Guide Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com Connect with Confidence...

Страница 2: ...ION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if not installed and used properly that is in strict accordance...

Страница 3: ...ation 4 3 1 Cabling Considerations 4 3 2 Making the Connections 4 3 2 1 Connections and Setup in General 4 3 2 2 Connections on the Single Port Video Audio 5 3 2 3 Connections on the Single Port Video...

Страница 4: ...red Destination Impedance Video IN 75 ohms Audio IN if any 600 ohms minimum Audio Characteristics Channels Right Left summed Line Level 600 Ohm Unbalanced Serial Characteristics Protocol Asynchronous...

Страница 5: ...bit much greater skew than standard CAT5 5e and may require skew compensation beyond what the standard product offers Please contact Magenta Research for assistance CAT5 5e 6 cabling for the Magenta M...

Страница 6: ...efer to the transmitter user guide 1 Connect the source video to the MultiView Series transmitter video input port which is an HD15 connector labeled SOURCE IN 2 If desired attach a local monitor via...

Страница 7: ...ls over CAT5 cable The audio signal is line level audio and powered speakers are required Figure 3 1 shows the MultiView Series UTx transmitter with Audio Transmitter connections and Figure 3 2 shows...

Страница 8: ...l Figure 3 3 shows the MultiView Series UTx transmitter with serial Transmitter connections and Figure 3 4 shows the MultiView 500S serial receiver connections See Appendix A for cable pinouts of the...

Страница 9: ...s inside the MultiView 500 receiver All adjustments are performed externally Table 3 1 MultiView 500 Receiver Configuration Settings 3 4 Video Adjustment The only adjustments required on the MultiView...

Страница 10: ...k input source levels from the source device Make sure the audio source is not overdriven or underdriven Audio is summed left and right for A versions If using a single channel both audio inputs must...

Страница 11: ...ideo connector Pin RGBHV VGA RGBS RGsB Com posite SVHS Y C YUV 1 Red Red Red C V 2 Green Green Green C Y Y 3 Blue Blue Blue U 4 5 Gnd Gnd Gnd 6 Red Red Red C V 7 Green Green Green C Y Y 8 Blue Blue Bl...

Страница 12: ...ble A 3 1 8 3 5 mm Audio Serial Connection model dependent Note The stereo audio input at the transmitter is summed and output as mono audio on both channels at the receiver Pin Signal Tip Serial Tx D...

Страница 13: ...nto the top cover Simply replace the top cover of the unit to install the mount bracket option Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient tem...

Страница 14: ...MAGENTA MULTIVIEW SERIES 12 NOTES...

Страница 15: ...13 NOTES...

Страница 16: ...MAGENTA MULTIVIEW SERIES Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com PN UL 5310204 01 Rev 02 Jan 2010...

Отзывы: