Magellan MG32LRF Скачать руководство пользователя страница 2

Wireless Keypad Signal Strength

To view the wireless keypad signal strength, see sections [575] to [578]

Wireless Keypad Options

To toggle wireless keypad supervision options, see section [580]:

Display Mode

To toggle Display Mode, see section [580]:

The MG32LRF has two display modes. By default, the keypad will show all events (e.g. zones in alarm, 
bypassed zones, etc.) live as they occur. Alternatively, with Live Display Mode off, the system will only 
display zones that cause an alarm or entry delay. If you want to see the status of all zones, press the [ ] 
key. Zones that are open but have not triggered an alarm will only be displayed after pressing the [ ] 
key. The display will appear for 30 seconds, showing the status of all zones at the time the [ ] key was 
pressed. The zone display will shut off after 30 seconds.

Power Save Mode

If the keypad’s DC adapter is not connected, the keypad’s display will shut off and go into power save 
mode after one minute to conserve battery life. Press the [ ] key to activate the display. 

IMPORTANT

: When the keypad is in power save mode, no events will be displayed. For example, alarms 

and entry delays will not be visible in power save mode. Press the [ ] key to activate the display and 
see the status of the system. 

Power / RxTx LED

On = Power of panel (not keypad).

Fast Flashing = Transmission/reception in progress.

Trouble

Group [16]: Wireless keypad communication failure.

 

[575]

Wireless Keypad 1 Signal Strength

[577]

Wireless Keypad 3 Signal Strength

[576]

Wireless Keypad 2 Signal Strength

[578]

Wireless Keypad 4 Signal Strength

RSSI - Receiver Signal Strength Indicator (1 = weak signal, 10 = strong signal)

Signal Strength

Keypad Audible Indicator

1 to 4 (relocate wireless keypad)

1 beep

5 to 7

2 beeps 

8 to 10

3 beeps

Option

OFF

ON (default)

[1]

Keypad 1 Supervision

N

Disabled

N

Enabled

[2]

Keypad 2 Supervision

N

Disabled

N

Enabled

[3]

Keypad 3 Supervision

N

Disabled

N

Enabled

[4]

Keypad 4 Supervision

N

Disabled

N

Enabled

Option

OFF

ON (default)

[8]

Live Display Mode

N

Disabled

N

Enabled

Technical Specifications

RF frequency

433MHz or 
868MHz

Range (typical in a 
residential environment)

40m (130ft)

Main Power Source 6Vdc (300mA)

Compatibility

Magellan MG5000 
(V1.30 or higher)

Backup Battery

3.7Vdc Li-ion 
rechargeable

Operating temperature

0°C to 49°C (32°F to 
120°F)

Standby Power 
(Backup Battery)

Up to 48 hours

paradox.com

Printed in Canada - 10/2006

  MG32LRF-EI00