background image

English

At the recommended height of 2.1m (7ft) ±10%, the MG-PMD75 motion detectors 
provide full coverage from 1.5m (5ft) to 11m (35ft). The installation height is measured 
from the center of the detector (Figure 1). 

Avoid placing the detector within proximity of the following sources of interference: 
reflective surfaces, direct air flow from vents, fans, windows, sources of steam/oil 
vapor, infrared light sources and objects causing temperature changes such as 
heaters, refrigerators and ovens.

Avoid bending, cutting or altering the antenna or mounting the detector near or on 
metal as this may affect signal transmission.
Do not touch the sensor surface as this could result in a detector malfunction. If 
necessary, clean the sensor surface using a soft cloth with pure alcohol.

PCB Height Adjustment

The MG-PMD75 is designed for optimal performance at a height of 2.1m (7ft), but can 
be installed lower or higher. After you have installed the detector, ensure that the 
adjustable height markings on the right side of the PCB matches the tab inside the 
back cover (see 

“H” 

in Figure 1). For example, if the detector is installed at a height of 

2.1m (7ft), the PCB should then be adjusted to 2.1m (7ft) (Figure 1). Align the desired 
marking (height) with the back cover’s plastic tab. If another installation height is called 
for, readjust the PCB accordingly. Any PCB adjustments should be followed by a walk-
test of the protected area. Walk-testing verifies that the required coverage is in place. 

LED Setting (J5)

This setting enables or disables the red LED (Table 1). The red LED will illuminate for 
a period of 4 seconds to indicate detected movement. The motion detector performs a 
battery test every 12 hours. If the battery voltage is too low, the red LED will flash at 5-
second intervals and the motion detector will send a low battery signal to the receiver. 
A trouble will then be generated and transmitted to the central monitoring station. The 
red LED will flash rapidly when the motion detector transmits a signal to the receiver.

Digital Shield™ Setting (J4)

In Normal Shield mode, the detector is set for normal environments. In High Shield 
mode, the detector is set for high-risk environments (potential interferences) and 
therefore provides greatly increased false alarm immunity. However, response time 
and detector speed may be slower. Refer to Table 1.

Single or Dual Edge Processing (J3)

This setting determines the DSP (Digital Signal Processing) operational mode of the 
detector. Single Edge Processing mode should be used in normal environments with 
minimal sources of interference. Dual Edge Processing mode provides better false 
alarm rejection in the case where the detector is placed near sources of interference 
that can adversely affect the motion detector. Refer to Table 1.

Operating Mode (J2)

This jumper determines what model of wireless receiver the motion detector will be 
communicating with, Omnia or Magellan. Refer to Table 1.

Check-in Supervision Timer (J1)

Jumper J1 sets the time interval in which the detector communicates a check-in signal 
when used with Omnia or Spectra 1759EX (see Operating Mode).  Refer to Table 1.

If the detector is used with Magellan (see Operating Mode), J1 is disabled and the 
detector will regularly transmit a check-in signal to Magellan. The check-in supervision 
time is set in the Magellan console.

With an OMN-RCV3 V2.0 or higher, the receiver automatically detects the check-in 
time set in each of its assigned transmitters. As a result, the transmitters can have 
different check-in times. With a previous version of the OMN-RCV3,  the transmitter 
check-in time needs to match the setting in the module.

With an OMN-RCV3 V2.0 or higher, if the check-in time setting is changed, power 
down and then power up the receiver in order for the change to be recognized.

Powering the Detector

1. Insert 3 “AAA” batteries into the battery holder while verifying polarity (Figure 4).
2. Insert the battery holder into the back cover and affix the battery connector to the 

PCB (see 

“A1”

 and 

“A2”

 in Figure 4).

After connecting the battery connector, a power-up sequence will begin (lasting 10 
to 30 seconds). During this time, the red LED will flash and the detector will not 
detect an open zone or tamper.

Replacing Batteries

1. Disconnect the battery connector from the PCB. Remove the battery holder and 

remove the old batteries.

2. Press and release the anti-tamper switch to ensure that the unit has powered down.
3. Follow the steps outlined in “Powering the Detector”.

Walk-testing

Open the cover in order to trigger the anti-tamper switch, then snap the cover back 
into position. This will activate the motion detector’s walk-test mode for 3 minutes.
At 20°C (68°F), in Normal Shield (J4 = ON) mode and Single Edge Processing mode 
(J3 = ON), you should not be able to cross more than one complete zone (consisting 
of 2 beams, left and right sensor detecting elements) in the coverage area with any 
kind of movement; slow/fast walking or running. 

In High Shield mode, the amount of movement required to generate an alarm is doubled. 
The approximate width of a full beam at 11m (35ft) from the detector is 1.8m (6ft). When 
walk-testing, always move across the detection path and not toward the detector.

Walk-test mode is also activated for 3 minutes once the motion detector is powered 
on.

Signal Strength Test

In order to verify the receiver's reception of the motion detector’s signal, perform a 
signal strength test before finalizing the installation of the motion detector. Prior to 
performing the test, make sure the batteries have been inserted into the battery holder 
to power the detector. Also verify that the motion detector has been assigned to a 
zone. For more information on signal strength tests and zone programming, refer to 
the appropriate receiver’s

 Reference and Installation Manual. 

If the transmission is 

weak, relocating the transmitter by a few inches can greatly improve the reception.

Alive Software

If the motion detector transmits 2 alarm signals (LED on for 4 sec.) within a 5-minute
period, the detector falls into Energy Save mode where it won’t transmit any alarm 
signals for approximately 3 minutes. Due to the motion detector’s Alive Software, the red 
LED continues to flash to indicate a detection even when in Energy Save mode. Once 
the 3-minute Energy Save mode ends, the motion detector returns to normal operation.

If the detector’s cover is removed and then replaced while in Energy Save mode, the 
first detection will trigger an alarm signal.

 *

FCC ID: KDYOMNPMD75

     

Canada: 2438A-OMNPMD75

 

The MG-PMD75 complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful 
interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Battery life expectancy will vary according to the check-in time interval and the amount of traffic (movement) the detector has processed. A higher check-in 
time interval and higher traffic will lower battery life.

© 2002-2007Paradox Security Systems Ltd. Specifications may change without prior notice.
Changes or modifications on equipment not expressly approved by Paradox Security Systems could void the user’s authority to operate the equipment. Omnia, 
Spectra, Magellan and Shield are trademarks or registered trademarks of Paradox Security Systems Lts and its affiliates in Canada, the United Staes and other 
countries. All rights reserved. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 
5119069, 5077549 and RE39406 and other pending patents may apply. LODIFF® lens: patent #4,787,722 (U.S.). LODIFF® is a registered trademark of Fresnel 
Technologies Inc.

Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the 
Paradox product signifies your acceptance of all warranty terms and conditions.

Figure 1 / Figura 1

Figure 2 / Figura 2

Figure 3 / Figura 3

Figure 4 / Figura 4

Table/Tableau/Tabla 1

U

= default/par défaut/de fábrica

*

 = Omnia / Spectra 1759EX only

*

 = Omnia / Spectra 1759EX seulement

*

 = Sólo Omnia / Spectra 1759EX

After changing the jumper settings, snap on the cover to close the anti-tamper switch 
or press and release the anti-tamper switch in order to save the changes.

Après la modification des réglages des cavaliers, remettre le couvercle en place pour 
fermer l’interrupteur de sécurité ou enfoncer et relâcher ce dernier afin de 
sauvegarder.

Después de cambiar la configuración de los puentes, encaje la cubierta en su lugar 
para cerrar el interruptor antisabotaje o pulse y suelte el interruptor anti-sabotaje para 
guardar los cambios.

Digital Wireless Motion Detector 

with Pet Immunity (MG-PMD75)

V2.0

Instructions

Instrucciones

     paradox.com  

   Printed in Canada - 07/2007           MGPDM75-TI01

Technical Specifications

Sensor Type

Two dual opposed infrared sensors

Coverage - 90° (standard)

11m x 11m (35ft x 35ft)

Pet Immunity

Up to 40kg (90lbs)

Detector Speed

0.2m to 3.5m/sec. (0.6ft to 11.5ft/sec.)

Installation Height

2.1m to 2.7m (7ft to 9ft)

Operating Temperature

0°C to +50°C (+32°F to +122°F)

RF Frequency 

433* or 868MHz

 

Lens

2nd generation Fresnel lens, LODIFF®, segments

Power

3 X “AAA” alkaline batteries

Transmitter Range

35m (115ft) with MG-6130/MG-6160
70m (230ft) with MG5000 / MG5050 / MG-RTX3 

Anti-Tamper Switch

yes

Battery Life

Lowest check-in setting: 3 years
Highest check-in setting: 1.5 years

Certifications (i.e. UL and CE)

For updated information on certifications, go to 
www.paradox.com

Compatibility

MG-RTX3, MG5000, MG5050, MG-6130/MG-6160, MG-
6030/MG-6060,1759EX/1759MG, Omnia, MG-RCU3

C

- unit aims further, the gap between 

beams is wider. Pet immunity is 
compromised.

- l’unité capte plus loin et l’espace entre 

les faisceaux est plus grand; 
l’insensibilité aux animaux est 
compromise.

- el objetivo de la unidad está más lejos, 

la distancia entre haces es mayor. La 
inmunidad contra mascotas está 
comprometida.

B

- unit aims closer, the gap

between beams is smaller. Pet 
immunity is compromised.

- l’unité capte plus près et l’espace 

entre les faisceaux est plus petit; 
l’insensibilité aux animaux est 
compromise.

- el objetivo de la unidad está más 

cerca; la distancia entre los haces es 
más pequeña. La inmunidad contra 
mascotas está comprometida.

2.1m 

(7ft / pi.)

A

A

- optimum beam dispersion
- dispersion optimale du faisceau
- dispersión de haz óptima

3.1m 

(10ft / pi.)

B

1.1m 

(4ft / pi.)

C

2.1m 

(7ft / 
7 pi)

2.1m 

(7ft / 
7 pi)

2.1m 

(7ft / 
7 pi)

3m

 (10ft)

3m

 (10ft)

1.5m

 (5ft)

1.5m

 (5ft)

0m

(0ft)

0m

(0ft)

1.5m

 (5ft)

 3m 

(10ft)

6m

(20ft)

9m 

(30ft)

11m

(35ft)

90°

2.1m
 (7ft)

A

- corner mount
- montage en coin
- montaje en esquina

B

- flat surface mount
- montage sur surface plane
- montaje en superficie plana

C

- PCB height tab
- onglet pour hauteur de carte de 

circuits imprimés

- lengüeta de altura de PCI

A

A

A

B

B

B

B

C

A

LED Indicator / Voyant DEL / Indicador LED

J5

OFF =

disabled/désactivé/deshabilitado

ON = 

enabled/activé/habilitado 

U

Digital Shield (sensitivity) / Algorithme numérique Shield (sensibilité) / Digital 
Shield (sensibilidad)

J4

OFF = High Shield (low sensitivity) / Protection élevée (faible sensibilité)

Blindaje Superior (baja sensibilidad)

ON = Normal Shield (high sensitivity) / Protection normale (forte sensibilité)

Blindaje Normal (alta sensibilidad) 

U

Processing Type/Type de traitement/Tipo de Procesamiento

J3

OFF = Dual edge / divisé / polaridad doble
ON =  Single edge / simple / polaridad simple 

U

Operating Mode / Mode de fonctionnement / Modo de Funcionamiento

J2

OFF = Omnia / Spectra 1759EX
ON = Magellan 

U

Check-in Supervision Timer / Délai de supervision de présence / Tiempo de 
Verificación de Prescencia

J1

*

OFF = 12 minutes / minutos
ON =  12 hours / heures / horas 

U

A1, A2

- battery connector
- connecteur de piles
- conector de batería

B

- anti-tamper switch
- interrupteur de sécurité
- interruptor antisabotaje

C

- PCB height markings
- marques pour hauteur de 

carte de circuits imprimés

- marcas de altura de PCI

D

- antenna/antenne/antena

E

- sensors/capteurs/sensores

F

- LED/DEL/LED

G

- battery holder
- porte-piles
- compartimiento de batería

H

- PCB height tab
- onglet pour hauteur de carte 

de circuits imprimés

- lengüeta de altura de PCI

A1

B

C

D

F

E

A2

G

H

J5

J4

J3 J2 J1

- top battery
- pile du dessus
- batería de arriba

Отзывы: