† For UL installations, Tamper recognition options must be enabled.
‡ For UL installations, Wireless supervision options must be enabled.
* For UL installations, if the zone is programmed as a wireless fire zone, supervision must be enabled and the check-in supervision time must be set at 80
minutes (section
[096]
option
[7]
* For UL installations, if either or both of the hardwired zones are enabled, then section
[095]
option
[3]
option must be enabled.
† This feature only applies to Magellan’s onboard zone inputs. Section [095] options [1] and [2] must be ON in order to use this feature.
* This option must be enabled for UL installations.
[094]
Zone Options
Bold
= Default setting
Option
OFF
ON
[1]
Stay delay zones
Disabled
Enabled
[2]
Report zone restore
On Bell cut-off
On zone closure
[3] & [4]
Tamper recognition options †
See table
See table
See table
See table
[5]
Generate tamper trouble if detected on bypassed zone
No
Yes
[6] & [7]
Wireless transmitter supervision options ‡
See table
See table
See table
See table
[8]
Generate supervision trouble if detected on bypassed zone
No
Yes
[095]
Zone Options
Bold
= Default setting
Option
OFF
ON
[1]
Zone 15 is hardwire zone 1 *
Disabled
Enabled
[2]
Zone 16 is hardwire zone 2 *
Disabled
Enabled
[3]
EOL (End-Of-Line) resistors †
No EOL
Use EOL resistors
[4]
Stay arm siren delay
Disabled
Enabled
[5]
Boat/car mode
Disabled
Enabled
[6] to [8]
Future use
Future use
Future use
[096]
General Options
Bold
= Default setting
Option
OFF
ON
[1] & [2]
Doorbell 1 tone options
See table
See table
See table
See table
[3] & [4]
Doorbell 2 tone options
See table
See table
See table
See table
[5]
Daylight savings time
Disabled
Enabled
[6]
AC power failure warning *
Disabled
Enabled
[7]
Check-in supervision time
24Hrs
80 minutes
[8]
RF Interferences detection *
Disabled
Enabled
[097]
Reserved for future use
[3]
[4]
OFF
OFF
- Disabled
OFF
ON
- Trouble only
ON
OFF
- Disarmed: Trouble only
- Armed: Follow
zone’s alarm type
ON
ON
- Disarmed: Audible alarm
- Armed: Follow
zone’s alarm type
[6]
[7]
OFF
OFF
- Disabled
*
OFF
ON
- Trouble only
ON
OFF
- Disarmed: Trouble only
- Armed: Follow
zone’s alarm type
ON
ON
- Disarmed: Audible alarm
- Armed: Follow
zone’s alarm type
[1]
[2]
OFF
OFF
- Tone 1
OFF
ON
- Tone 2
ON
OFF
- Tone 3
ON
ON
- Tone 4
[3]
[4]
OFF
OFF
- Tone 1
OFF
ON
- Tone 2
ON
OFF
- Tone 3
ON
ON
- Tone 4