MagCore HF48 Скачать руководство пользователя страница 2

1

www.rbcbioscience.com

Safety Precautions

 Handle the power cord carefully.

Hold the plug when unplugging the cord.

Keep the set free from moisture, 

liquid, and dust.

Unplug the power cord if the system 

will not be used again in a long time.

Do not obstruct the ventilation space.

Do not let foreign objects in the set.

Do not let insecticides, benzene, or 

thinner come in contact with the set.

Do not ever disassemble or modify 

the set in any way.

 Avoid high temperatures.

Leave space for sufficient heat dissipation during installation.

CAUTIONS 

Risk Of Electric Shock

Do Not Open

Before use

WARNINGS and CAUTIONS stated below are intended to protect the individual from injuries 

and avoid damage to machines. 

CAUTION:

To reduce the risk of electric shock, do not remove the cover. Refer to qualified 

service technician for inner part servicing.

CAUTION:

1. Handle the power supply cord carefully

Do not damage or twist the power supply cord. Damaged or twisted cord may 

cause electric shock or error when used. When you remove it from the outlet, be 

sure to remove by holding the plug and not by pulling the cord.

2. Do not open the top cover

In order to prevent electric shock, do not open the top cover.

3. Do not place anything inside

Do not place metal objects inside the MagCore

®

 System and wipe away all spilled 

liquid to minimize the risk of system error and electric shock.

Note On Use:

1.  Read Instructions

 – All the safety and operating instructions should be read 

before operating the instrument.

2.  Keep the Instructions 

– Please keep the safety and operating instruction 

manual for future reference.

3.  Cautions and Warnings 

– All warning signs should be attached on the 

product and shown in the user's manual.

4.  Follow Instructions

 – All operating and use instructions should be followed.

5.  Cleaning

 – Unplug the product before cleaning. Use only 75% of  EtOH to 

clean the surface of instrument.

6.  Attachments

 – Do not attach anything on the instrument.

7.  Liquid and Moisture

 – Do not use this product near water and avoid moist 

areas - bath tub, wash bowl, kitchen sink, laundry, swimming pool or in a moist 

basement.

8.  Proper Installation

 – Do not place this product on an unstable cart, stand, 

tripod, bracket, or table. The product may fall and caues serious injury to a child 

or adult, and serious damage to the product. Use only with a cart, stand, tripod, 

bracket, or table recommended by the manufacturer, or sold with the product. 

Any mounting of the product should follow the manufacturer’s instructions, 

and should use a mounting tool recommended by the manufacturer.

9.  Ventilation

 – Slots and openings in the cabinet are designed for ventilation, 

which is required for safe operation and minimizing the chance of overheating. 

The product should be placed on a hard surface to ensure proper ventilation. 

This product should not be placed in a built-in installation such as a bookcase 

or rack unless proper ventilation is ensured or instructed  by the manufacturer.

10. Power Sources

 – This product should be operated only from the type of power 

source indicated on the label. If you are not sure of the type of power supply at 

your lab, consult the seller or local power company. For products intended to 

operate from battery or other sources, refer to the operating instructions.

11. Grounding or Polarization

 – This product may be equipped with a polarized 

alternating-current plug. This plug will fit into the power outlet in one way only. 

This is a safety feature. If you are unable to insert the plug fully into the outlet, 

try reversing the plug. If the plug should still fail to fit, contact your electrician to 

replace your obsolete outlet. Do not defeat the safety purpose of the polarized 

plug.

12. Power-Cord Protection

 – Power-supply cords should be routed so that they 

are not likely to be walked on or pinched by items placed near or against them. 

Pay extra attention to the plugs, convenience receptacles, and the connecting 

point where the cord extends out of the product. 

13. Lightning

 – Unplug the product if it will not be used again for a long period or 

in the case of a heavy storm. This will prevent damage to the product due to 

lightning and power surges.

14. Overloading

 – Do not overload wall outlets, extension cords, or integral 

convenience receptacles as this can result in a risk of fire or electric shock.

15. Object and Liquid Entry

 

– Never push objects of any kind into this product as 

they may touch dangerous voltage points or short-out parts that could result 

in a fire or electric shock. Never spill liquid of any kind on the product.

16. Servicing

 – Do not attempt to repair this product by yourself. Refer all servicing 

to qualified service technician.

17. Damage Requiring Service

 – Unplug this product from the wall outlet and 

refer servicing to qualified service technician under the following conditions:

a)

 When the power-supply cord or plug is damaged,

b) 

If liquid has been spilled, or objects have fallen into the product,

c) 

If the product has been exposed to rain or water,

d)

 If the product does not operate normally following the operating 

instructions. Adjust only  controls covered by the operating instructions as an 

improper adjustment of other controls may result in damage and will often 

require extensive work by a qualified technician to restore the product to its 

normal operation, 

e)

 If the product has been dropped or damaged in any way, and

f)

 When the product exhibits a distinct change in performance 

– this indicates a need for service.

18. Replace Parts 

– When replacement is required, be sure the service technician 

uses replacement parts specified by the manufacturer or those with similar 

features as the original part. Unauthorized substitutes may result in fire, electric 

shock, or other hazards.

19. Safety Check

 – Upon completion of any service or repairs to this product, ask 

the service technician to perform safety checks to confirm that the product is in 

proper operating condition.

20. Heat

 – The product should be situated away from heat sources such as 

radiators, heat registers, stoves, or other products that produce heat.

General Warning

Warning: Biological Hazard

Warning: High Temperature

Warning: Electricity

SAFETY INSTRUCTIONS

Содержание HF48

Страница 1: ...tallCartridge 7 TouchPanelandUserInterface 8 Main Menu 8 PanelFunctionalArea 8 EmergencyStopandWarning 9 Start 10 LoadProgram 11 SavePrograms 12 DeletePrograms 12 Update Program Files 13 EasyMaintenan...

Страница 2: ...erSources Thisproductshouldbeoperatedonlyfromthetypeofpower sourceindicatedonthelabel Ifyouarenotsureofthetypeofpowersupplyat your lab consulttheseller or local power company For products intended to...

Страница 3: ...ationParameters OperationEnvironment Applications Whole Blood DNA Viral Nucleic Acid DNA RNA 200 l 400 l 1200 l Plasma and Circulating Cell Free DNA 1200 l Tissue Genomic DNA Plant Genomic DNA Bacteri...

Страница 4: ...Tip TipHolderSet X50 ElutionCarrier X1 CartridgeCarrierB X1 CartridgeCarrier A X1 Tip Carrier B X 1 TipCarrierA X 1 PowerCord X 1 Lubricant X1 O Ring X24 Systemtesttoolsshouldbekeptincleanplacesandth...

Страница 5: ...Shutter Leveling Glides four legs Fixed Knob on the Top Cover of Part Chamber SystemOverview Cooling Fans Power Switch and Plug Power Switch red Light Switch green Part Chamber Maintenance Cover Stat...

Страница 6: ...on close to outlets and leave sufficient space for system installation and heat dissipation Pleaesuse theleveling glidestofine tune theelevationlevel System Height 160 cm System Depth 80 cm System Wid...

Страница 7: ...etheelevation Remembertotightenthescrews Cutthefixationbeltandclosethetopcoverofpartchamber Cutthefixationbeltsontheracks Pluginthepowercordandturnonthemainpower Turnonthepowerandthesystemwillstartini...

Страница 8: ...areaA Carrierofarea B canonly be used in area B Incorrect usemay causesystem error Install Cartridge Install Tipand SampleTube InsertTipsandSampleTubesintotheslotsintheTipCarrier Then placetheTipCarr...

Страница 9: ...m Load frequently used programs stored by user Maintenanceandothertestfunctions Basicmaintenance UVsterilization and systemtests Systemtime Systemstatus Basicsysteminformation serialnumber errormessag...

Страница 10: ...2 Resume Thesystemwillstopalloperations immediatelyifthefrontdoorisopened SelectContinuetoresumetoprevious operationsorAborttoendalloperations PressStopkeytostopalloperationsimmediately incaseofemerge...

Страница 11: ...ratethesystemifthe parametersarecorrect PleasepressNotomodifyincorrect parameters Youmaymonitortheextractionprogressandchecktheremaining timeonthescreen ThesystemwilldisplayCompletepageafter completio...

Страница 12: ...arecorrectandpressYes Please select Cartridge Code Please select Channel NextStep NextStep Load Program Youcansavefrequentlyusedprogramswithnamesyoupreferforyour convenience PressLoadProgramtoenterthe...

Страница 13: ...ktomodify Confirmiftheparametersarecorrect EnterthenameyouwanttosaveandpressEnter SavePrograms Please select Channel Youmaydeleteyoursavedprogramaswell PleasepressLoadProgramstoenterStoredProgramspage...

Страница 14: ...neby users Theseitemsincludesterilization cleaning systemtests errormessage report etc Usersmustperformtheseitemsregularlytoensurethatthesystem canfunctionnormally UpdateProgram Files UV Sterilization...

Страница 15: ...rings PressFinishafterapplyinglubricant ReplaceO Rings SelectCleanPiercingNeedlesandpressSTART Pleaseprepareacottonpaperwith70 alcoholtoclean Clean PiercingNeedles NextStep NextStep NextStep NextStep...

Страница 16: ...ipssmoothly Ifyes pressNext Ifyou findanytipstuckinitstipholder pressAborttostopthetestand replacethetip tipholder Runthetestagainandiftheproblem persists contactyourlocaldistributorfortechnicalsuppor...

Страница 17: ...mparewiththevalueonyourthermometer toseeiftheyarethesame PleasepressStopifyouwanttostopthetest HeaterTest Thisfunctionisforthesystemtoreturntipstotheiroriginal locationsafteremergencystoporoperationin...

Страница 18: ...ostopifyouwanttostopsterilization UV Sterilization OpenthetopcoverofthePartChamber ReplacetheoldUVlampwithanewone SelectStatusinthemainmenuandpressUVTimeResetkeyto resetthehoursofUVlamp Pleasetesttose...

Страница 19: ...sfunctionifyouneedtoraiseor lowerthedrippan Refertothepage7forcorrespondinglocationsofoperationareas SelecttheareayouwanttomoveupordownandpressStart Itwill stopautomaticallywhenthemotormovestoend Movi...

Страница 20: ...ce com Selecttheitemsyouwishtochange EntersettingvalueandpressEnter SystemTiming Setting YearSetting MonthSetting DaySetting 12or24hourdisplayformat MinuteSetting HourSetting NextStep NextStep Setup Y...

Страница 21: ...videthefilefor engineerstodetermineandsolveerrorsinthesystem Systemdate Systemtime Machineserialnumber PLCversion UIversion UVlampoperatingtime UVlampoperatingtime Errormessagelistoutput NextStep Next...

Страница 22: ...ied for replacement Using fuses with higher amps maycausedangerofburning ReplaceFuses Others Youcanusethebarcodescannertoinputyoursample scodeinto thetestreport Select BarcodeScan functionandenter Bar...

Страница 23: ...rtoolong 1 Checksuctionhead 2 Please refer to system test and check if the liquid level is thesamethroughouttips 3 Renewyourreagents Liquidlevelfloodsovertipfilter 1 Wrongsamplematerials 2 Wrongsample...

Страница 24: ......