background image

TDC series user manual rev 1.0

6

M

A

G

 T

H

E

A

TR

O

N

Panel D. Audio and Ethernet connection

Input connectors, unbalanced

+ Ch1

+ Ch2

shield Ch1

shield Ch2

Input connectors, balanced

+

-

sh

iel

d

2

3

1

Through connectors, balanced

+

-

sh

iel

d

2

3

1

A

U

DI

O

 A

ND

 E

THE

R

NE

T C

ONNE

C

TI

ON

Содержание TDC Series

Страница 1: ...Power amplifiers TDC series User manual TDC 1200W TDC 3200W Models THEATRON...

Страница 2: ...Menu diagram 18 7 2 Event screen 18 7 3 AMPLIFIER MENU 18 7 3 1 AMP SETTINGS submenu 18 7 3 2 METERS submenu 18 7 3 3 INFO submenu 18 7 3 4 NETWORK submenu 19 7 3 5 SIGNAL GENERATOR submenu 19 7 3 6...

Страница 3: ...TDC series user manual rev 1 0 3 MAG THEATRON Panel A Dimensions DIMENSIONS...

Страница 4: ...dio controls 6 band parametric EQ volume polarity delay DSP utility controls Power saving mode power up mode Input sensitivity 5dBu 7dBu Maximum input level 20dBu Input impedance 18 kOhm unbal 36 kOhm...

Страница 5: ...button 1 Mains switch 2 Mains plug 3 Output Phoenix connector 4 Channel 1 unbalanced RCA input 5 Channel 2 unbalanced RCA input 6 Channel 1 balanced XLR female input connector 7 Channel 2 balanced XL...

Страница 6: ...1 0 6 MAG THEATRON Panel D Audio and Ethernet connection Input connectors unbalanced Ch1 Ch2 shield Ch1 shield Ch2 Input connectors balanced shield 2 3 1 Through connectors balanced shield 2 3 1 AUDI...

Страница 7: ...EN WHITE 2 ETH TX GREEN 3 ETH RX ORANGE WHITE 4 not connected BLUE 5 not connected BLUE WHITE 6 ETH RX ORANGE 7 not connected BROWN WHITE 8 not connected BROWN 568A 568B Loudspeaker connection bridged...

Страница 8: ...ress to return to the AMPLIFIER menu simultaneous pressing the button 1 and the 2 button for controlling two channels Turn to display the AMPLIFY menu or use to edit the parameters for DSP menu if not...

Страница 9: ...rname Channel 2 Edit the unit name Selection Name Standart names 3 Selection Name Range 19 25 if present Ethernet module 4 Network Amplifier identifier editor 4 1 Exit Save Amplifier menu 16 Ohm 1 Ohm...

Страница 10: ...TDC series user manual rev 1 0 10 MAG THEATRON...

Страница 11: ...SONNEL FOLLOWING APPLICABLE SAFETY RULES DO NOT ALLOW INSTALLATION OF THIS UNIT IF INSTALLATION HARDWARE IS BROKEN BENT PARTS ARE MISSING OR IS OTHERWISE DAMAGED The triangle with the lightning bolt i...

Страница 12: ...user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Con...

Страница 13: ...ques and adds advanced DSP and controls so projects are more streamlined with reduced total costs Efficient class D amplification provides for less environmental footprint and along with smart standby...

Страница 14: ...he temperature detected by the sensors rises over carefully predetermined values This ensures that fan noise and internal dust accumulation are kept to a strict minimum Shouldhowevertheamplifierbesubj...

Страница 15: ...sively by earth connected mains sockets in electrical networks compliant with the IEC 364 or similar rules Install the amplifier into a rack cabinet With a TDC amplifier a sectioning breaker between t...

Страница 16: ...log inputs are provided with two RCA connectors Refer to panel D for proper RCA pinouts 5 4 Analog balanced output through Balanced analog outputs for sending the signal to another amplifier are provi...

Страница 17: ...elect buttons opens the Channel menu for that channel Pressing both Channel buttons at the same time opens a Channel menu for controlling the parameters of both channels at the same time 6 1 Front LED...

Страница 18: ...off the standby and energy saving modes S t a n d b y O F F E n e r g y S a v e O F F 7 3 2 METERS submenu 7 Using the frontal menu Shows information about temperature and impedance load Screen 1 amp...

Страница 19: ...splay contrast EventScreen turn on and off the event screen Screen 2 change the channel name shown on the event screen and in the Web UI N a m e E d i t o r N o S u b n e t m a s k 2 4 2 5 5 2 5 5 2 5...

Страница 20: ...amplifier Note The password lock in the PASSWORD submenu is only applicable to the amplifier s menu itself and does not affect the functions of the Web UI 7 3 8 SYSTEM UNIT submenu Allows to choose m...

Страница 21: ...menu Reserved for future use 7 4 6 PEQ BAND 1 6 submenus Controls the parametric equalizer of the selected channel O F F P e a k G n 1 0 F q 1 0 0 0 Q u 1 5 On Off Turn the PEQ band on or off Peak Low...

Страница 22: ...eries amplifier before attempting the connection to the Web UI 8 2 Connecting to the Web UI Enter the TDC amplifier IP address in the address bar of your browser The pop up window will appear requesti...

Страница 23: ...source window allows one to choose the input and control the input gain for both channels It also gives access to the signal generator 8 3 2 Channel windows Two windows for each output channel provide...

Страница 24: ...and status messages channel protect channel mute signal on input indicator and sleep indicator Standby mode and energy saving mode can also be switched from the Monitoring window 8 3 4 Config window...

Страница 25: ...address network submask and gateway IP It is also possible to switch between static IP and dynamic IP mode Misc config tab allows changing the MAC address and to set the custom username and password t...

Страница 26: ...ows M A G N E T c o m v f m Where MAG NET Marker stating start of the remote control command com name of the command v value to set fm Finish marker of the command 9 5 Finish markers MAG Cinema Macrop...

Страница 27: ...om defects in material components and factory workmanship under the normal use and maintenance for the time as specified below All warranty repairs and maintenance of MAG Cinema products shall be carr...

Страница 28: ...2 Merezhna str Bila Tserkva Kyiv region 09100 Ukraine Tel Fax 38 044 2774789 e mail info mag theatron com www mag theatron com THEATRON...

Отзывы: