Connection plate
Cable gland cover
Installation of
cable gland cover
1. PHOENIX TERMINAL: Connect the 2-wire cable from amplifier
here.
2. CABLE GLAND: Put the cable through cable gland for water
sealed signal connection.
3. Use six screws (included) to install the cable gland cover onto
the connection plate
DSP AMPLIFIER
Z series passive
full-range system
Z series passive
subwoofer
Z series passive
subwoofer
FD series passive connection diagram
5.8.1. Passive connections
Use power amplifier with DSP or power amplifiers
with external speaker processor with FD series
systems.
MAKE SURE TO USE HIGH PASS FILTER FOR ALL
FD SERIES SYSTEMS TO PREVENT EXCESSIVE
CONE MOVEMENT, RESULTING IN TRANSDUCER
DAMAGE OR FAST DETERIORATION.
Recommended HPF settings, suggested power
amplifier ratings, and connection pins are found in
the table below:
System
Amplifier power
Amplifier impedance
Connection pins
Recommended HPF
FD-52
500 - 1000 W
8 Ohm
+ -
55 Hz or higher, 18 dB/oct min
FD-S15
1000 - 2000 W
8 Ohm
+ -
40 Hz or higher, 18 dB/oct min