9
EN
Network Data
Power
S
e
n
s
o
r
1
+
R
S
e
n
s
o
r
2
USB Data
GND
PNP
Output
NPN
Output
Example B
Description: Power is supplied only once to ORION and also used for the input equipment. Each Port
is protected with 500 mA max. To Port 1, a PNP output sensor is connected over 0 V – 12 V.
To Port 2, an NPN output sensor with an open collector is connected plus a 1k Ω – 10k Ω resistor.
Network Data
Power
USB Data
S
e
n
s
o
r
D
C
/A
C
GND
PNP
Output
Example C
Description: Power is supplied to ORION and supplied separately to the input equipment. The sensor
is connected to Port 1 via Ground and Signal at Pin 1, but not V+!
Network Data
USB Data
GND
PNP
Output
+
PNP
Output
+
GND
S
e
n
s
o
r
1
+
S
e
n
s
o
r
2
GND
Example D
Description: 5 V – 24 V power is supplied externally and to all input equipment. For example, a sensor
is connected to Port 1 via Ground, Signal at Pin1, and V+ to supply power to ORION once, while a
second sensor is connected to Port 2 via Ground and Signal at Pin 5, but not V+!