![MadMan EMS-3 Скачать руководство пользователя страница 22](http://html2.mh-extra.com/html/madman/ems-3/ems-3_operating-manual_3341614022.webp)
Madman EMS-3 Operating Manual
Page 22
Message type=128
Data Length=29 bytes
Output Rate=1Hz
Unused channels will read 0
Hour Meter Hours:
Unsigned Int (16 bits), Hour meter hours
Hour Meter Minutes:
Unsigned char (8 bits), Hour meter minutes
Service Time:
Unsigned Int (16 bits), Service time in hours
Volts:
Unsigned Int (16 bits), Volts in 0.1V
Analog Channel Type: Unsigned Int (16 bits)
CH4 (4 bits), CH3 (4 bits), CH2 (4 bits), CH1 (4 bits)
0=Off
1=Pressure
2=Temperature
Analog Channel 1:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Analog Channel 2:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Analog Channel 3:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
Analog Channel 4:
Signed Int (16 bits)
Pressure in 0.1psi
Temperature in Degrees C
CJC:
Signed Int (16 bit), Cold junction temperature in Degrees Celsius
EGT:
Signed Int (16 bit), EGT in Degrees Celsius
RPM:
Unsigned Long (32 bit), RPM value
RPM (%):
Unsigned Int (16 bit), RPM value in percentage
CLD:
Unsigned char (8 bits), 0=CLD alarm off, 1=CLD alarm on
Oil Pressure Switch:
Unsigned char (8 bits), 0=Oil Pressure switch off, 1= Oil Pressure switch on