2. Placing the unit and water connections
a.
Placing the unit and fixing
•
The frame must be fixed by bolts (M10) to a concrete foundation or brackets. The concrete
foundation must be solid and fastened; the bracket must be strong enough and anti-rust treated.
•
Do not stack substances that will block air flow near the inlet or outlet area, and there should be
no obstuction within 50cm behind the machine. Suffication of air reduces the efficiency of the
heater and could damage the unit.
•
If the machine needs an appended pump (not supplied). The recommended pump must adhere
to the specification-flux, please refer to the Technical Parameters.
b. Water connections and condensation
•
The inlet and outlet water unions should not be installed with soft flexible pipes. The heat pump
must
be connected with rigid pipes!
•
When the machine is running, condensation is created and discharged from the bottom. Please
place the drainage nozzle (accessory included) into the hole and clip it well, then connect a pipe
to drain the condensation water away.