background image

 

 

 
 
 
 

 

 

 

 

 

Summer Eco 

INVERTER POOL HEAT PUMP 

 

 

 
 
 

 

 

USER'S MANUAL

 

 

Содержание Summer Eco SUME60/240MM

Страница 1: ...Summer Eco INVERTER POOL HEAT PUMP USER S MANUAL...

Страница 2: ......

Страница 3: ...1 1 Installation requirments 11 2 Placing the unit and water connections 12 3 Wiring 13 4 Electric wiring Diagram 13 5 Reference for protecting devices and cable specification 13 E Operation guidance...

Страница 4: ...he Madimack high efficiency inverter pool heat pump All our heat pumps are built and designed to the highest standard and are protected by our extended warranty service for peace of mind We hope you e...

Страница 5: ...ion to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury or injury to a third party These signs are rare but are extremely important a Kee...

Страница 6: ...ed and may damage the machine h Do not use or stock combustible gas or liquids such as thinners paint and fuel to avoid fire i In order to optimize the heating effect please install heat preservation...

Страница 7: ...side the heat pump may be damaged 2 Accessories 3 Features a Stable DC inverter compressor b EEV Technology c Quick hot gas defrosting with Saginomiya 4 way valve d High efficiency twisted titanium he...

Страница 8: ...emperature range of ambient Air 15 25 5 Introduction of different modes a The heat pump has two modes Boost and Silence b They have different strengths under different conditions Mode Modes Strength B...

Страница 9: ...er kW 0 21 1 07 0 29 1 50 0 32 1 67 0 45 2 38 0 50 2 60 0 62 3 21 0 76 4 25 Rated input current A 0 94 4 88 1 32 6 82 1 47 7 58 2 05 10 80 2 27 11 84 2 80 14 61 3 44 19 32 Maximum input current A 6 5...

Страница 10: ...bject to adjustment periodically for improvement without further notice A B C D E F G H SUME60 240MM 324 560 348 349 872 250 74 654 SUME80 240MM 324 560 348 349 872 250 74 654 SUME100 240MM 324 560 34...

Страница 11: ...dards of their current state or local governing body for all electrical mechanical and water services to prevent danger or damage to the unit a Location and clearances The inverter pool heat pump shou...

Страница 12: ...air reduces the efficiency of the heater and could damage the unit If the machine needs an appended pump not supplied The recommended pump must adhere to the specification flux please refer to the Te...

Страница 13: ...5 Reference for protecting devices and cable specification Above data is subject to modification without notice Note The above data is associated to power cables less than 10m If power cable is longer...

Страница 14: ...bol Designation Function ON OFF Power On Off Boost Mode Press to start Boost mode Silence Mode Press to start Silence mode UP DOWN Temperature Setting Displaying Attention The controller has a built i...

Страница 15: ...mode is set to full power boost mode b Defrosting Automatic active defrosting When machine is defrosting starts flashing after defrosting is on continuously Forced defrosting When the machine is heati...

Страница 16: ...your local service center 3 Trialrun a The circulation pump must start before the heat pump and stop after the heat pump to avoid any damage occurring to the machine b Before starting the heat pump pl...

Страница 17: ...ough water flow is detected The Heat Pump has a large range operation up to a seven degree differential If the temperature differential is above 8 degrees the flow switch or E6 Error will be displayed...

Страница 18: ...bolts cables and connections regularly 4 If repairs or removal is required please contact an authorized service center 5 Do not attempt to work on the equipment by yourself Improper operation may cau...

Страница 19: ...tion d Vacuum system completely before welding Welding should only be carried out by professional person in a service center 2 Failure solution and code Failure Reason Solution Heat pump doesn t run N...

Страница 20: ...e 7 P0 Controller communication failure 8 P1 Water inlet temp sensor failure 9 P2 Water outlet temp sensor failure 10 P3 Gas exhaust temp sensor failure 11 P4 Evaporator coil pipe temp sensor failure...

Страница 21: ...I Appendix Power Cable Breaker fuse Not Supplied Earth Power Supply 230V 50Hz Water pump 230V less than 500W Water Pump Water Pump Breaker fuse Not Supplied Power Supply 230V 50Hz Earth...

Страница 22: ...Breaker fuse Not supplied Earth Power Supply 230V 50Hz Water pump 230V over 500W Water Pump Water Pump Breaker fuse Not supplied Power Supply 230V 50Hz Earth Power Cable Contactor...

Страница 23: ...on 1 Water pump timer 2 Water pump wiring of Heat Pump Note The installer should connect 1 parallel with 2 as above picture To start the water pump condition 1 or 2 is connected To stop the water pump...

Страница 24: ...Components c Installation Green Network connection Orange No network Red Failure Screw base on back panel Slide WIFi box into base Connect cable b Installation position Base Terminal WiFi Box WiFi But...

Страница 25: ...ill flash Android mobile please download from iPhone please download from b Enter Configure new device in APP follow indication to finish binding Select WiFi Select WiFi No device if already configure...

Страница 26: ...speak to your electrician to expand WiFi network 2 The weather forecast is for reference only This App is subject to updating without notice On Off Weather Temperature setting Timer Mode Setting Menu...

Страница 27: ...www Madimack com au...