4.  CONNECTING TO POOL PUMP                                                                                                                                             
 

Please  follow  these  steps  and  the  wiring  diagram  for  the  correct  connection.  The  warranty 
may be compromised if the device is not installed in accordance with instructions described in 
this manual. 
 
Only ONE pump can be connected to the inverter. Please do not connect any other appliance 
to the output.

 

 
Mark the hole locations on the wall with the template provided, drill and insert the expansion 
plugs supplied, fit the screws and hang the device on the screws. 
 
 
4.1  Turn off all electrical supply to the pool pump, unplug the pool pump it from the main 

switch or at the chlorinator which provides electrical power to the pump. 

 
4.2  Plug  the  pool  pump  into  the  device’s  “Power  socket”  see  fig  3  below  (PUMP 

CONNECTION ONLY). 

 
4.3  Plug  the  device  into  the  main  switch/chlorinator/timer  connection  where  the  pump  was 

originally plugged into.

 

 

4.4  Switch power back on. 
 
4.5  Ensure chlorinator/timer is active which will put power the controller 
 
4.6  Now the device is ready to operate and will illuminate 
 

 

Fig. 3 

Above figure is for reference only, plug & socket may vary for different countries/regions. 

 
 

Power plug 

Pump socket 

12mm 

Screw 

Screw 

Expansion plug 

Содержание INVPLUS1100

Страница 1: ...INVERTER INSTALLATION USER GUIDE INVPLUS1100 INVPLUS2200 Thank you for purchasing our variable speed pump controller Please read the manual carefully before installation operation and keep it for future reference after installation ...

Страница 2: ......

Страница 3: ...G TO POOL PUMP 3 5 SETTINGS OPERATION 4 6 PROTECTION ERROR CODES 7 7 COMMISSIONING AND CHECKS 8 8 EXCLUSIONS 8 9 WARRANTY 8 10 RECYCLING 8 SAFETY SYMBOLS Read and keep the manual in a safe place Warning Caution Risk of electrical shock Do not touch the heat sink e Waste Dispose at recycling centre ...

Страница 4: ... typical single speed swimming pool pump motor Fig 1 1 1 It is NOT compatible with a Single phase motors with centrifugal switch b Pool pump motors with start relays or switch c Series or DC motors d Pool pump motors with faults in their rotors or capacitors e Shaded pole asynchronous motors 1 2 An RCD with a rated residual current not exceeding 30mA must be used with this product Running Capacito...

Страница 5: ...f the inverter Fig 2 Model INVPLUS1100 INVPLUS2200 Dimensions Input power 1 phase AC 1 phase AC Input voltage 220 240V 220 240V Input frequency 50Hz 50Hz Output power Max 1 1kW Max 2 2 kW Output Voltage 1ph 0 240V 1ph 0 240V Pump type Single phase Single phase Max current Max 6A Max 12A Speed range 1200 2900 rpm 1200 2900 rpm Cooling Ventilation Ventilation Fan Net Dimension L H W 187 110 155mm 18...

Страница 6: ...crews 4 1 Turn off all electrical supply to the pool pump unplug the pool pump it from the main switch or at the chlorinator which provides electrical power to the pump 4 2 Plug the pool pump into the device s Power socket see fig 3 below PUMP CONNECTION ONLY 4 3 Plug the device into the main switch chlorinator timer connection where the pump was originally plugged into 4 4 Switch power back on 4 ...

Страница 7: ...ock the screen Press to start Upon starting pump will run at maximum speed of 2900 rpm for one minute self priming This can be increased to 10 minutes see Parameter settings Section 5 5 After self priming press to choose a running speed use or arrows to adjust by 50rpm increments to a specific running speed Once the pump has finished priming the inverter will automatically switch the pump to the p...

Страница 8: ...ds to save settings automatically A flashing indicates the device is waiting for start time Step5 press to check all 4 timers to ensure there are no invalid setting Note If inactivate for 1 minute the screen will lock automatically Hold for 3 seconds to unlock the device The device has power off memory operation will resume upon power restoration Under OFF mode hold for 3 seconds to retrieve facto...

Страница 9: ... 3 4 to COM Do not touch the heat sink while the device is in operation or until at least 30 mins after it has been switched off Keep it out of reach of children Because of high voltage conversion components contained in the device do not try to disassemble or replace any components in case of malfunction or breakdown Before serving on the unit wait till the power light turned off or at least 3 mi...

Страница 10: ...ng error Contact your supplier 9 E204 Keyboard EEPROM reading failure Contact your supplier 10 E205 Communication error Contact your supplier 11 AL01 Auto speed reduction against high temperature Contact your supplier Note 1 AL01 is not an error indication when it appears the inverter will automatically switch to a lower speed to self protect against high internal temperature When the temperature ...

Страница 11: ...e product its performance or the contents of the User Guide without notice in case of technical upgrade Madimack are not responsible for the failure of any pump connected to the device The variable speed controller should not be installed in exposed locations or corrosive environments 9 WARRANTY The Madimack variable speed pump controller is warrantied for manufacturing defect for up to 12 months ...

Страница 12: ...MA001 ...

Отзывы: