5.2 Startup
5.3 Self- priming
5. SETTING AND OPERATION
The default flow range for Madimack Inverflow Pro
is as below:
Model
Default flow rate range
80~320
80~420
80~520
L/min
L/min
L/min
When the power is switched on, the screen will fullu illuminate
for 5 seconds, check whether power supply voltage and
frequency conform to the nameplate;
Refer to section 4.4 before proceeding.
Before operation
.
Fill the basket with water before starting up the pump.
When the screen is locked, only the button will light up;
Press and hold for more than 3 seconds, other buttons
will all light up. The screen will automatically lock up when
there is no operation for more than 1 minute and the
brightness of the screen is reduced by 1/3 of the normal
display. Short press to wake up the screen and observe
the relevant operating parameters.
When switched on for the first time after installation, the pump
will start self-priming.
Self-priming:
When the pump performs self-priming, it will count down
from 1500s and stop automatically when the system detects
the pump is full of water, then the system will recheck for
120s again to make sure the self-priming is completed.
User can exit self-priming manually by pressing for more
than 3 seconds. The pump will enter the default Manual-
Inverter mode at the initial startup. If the user exits the self-
priming in the subsequent startup, the pump will return to
the previous state before the last shutdown.
Remark:
The pump is delivered with self-priming enabled. Each time
the pump restarts, it will perform self-priming automatically.
The user can enter the parameter setting to disable the default
self-priming function (
see 5.10
).
If the default self-priming function is disabled, and the pump
has not been used for a long time, the water level in the strainer
basket may drop. User can manually activate the self-priming
function by pressing both for 3 seconds, the adjustable
period is from 600s to 1500s (default value is 600s). After the
manual self-priming is completed, the pump will return to the
previous state before activating the manual self-priming. If the
pump has entered the Auto-Inverter mode previously, the pump
will perform self-learning for 180s to redefine the adjustable flow
range after the manual self-priming.
User can press for more than 3 seconds to exit the manual
self-priming, and the pump will run the same as the manual
self-priming is completed.
Power Consumption
Running capacity/ Flow rate
WIFI Indicator
Unit of flow
Timer period
Timer 1/2/3/4
On/ Off
Timer setting
To change the value (capacity/flow/time).
UP
DOWN
Switch between Adaptive Mode and Manual Mode .
Auto Inverter Mode:
The running capacity will be automatically
adjusted between 30%-120% according to the
preset flow rate.
Manual Inverter Mode:
The running capacity will be set manually
between 30%-120%.
The default mode is Adaptive mode.
3
3
1
5
2
2
5
4
4
6
6
5.1 Display on control panel:
Backwash/ Unlock
Hold down this button to unlock the screen.
Single press for Backwash activation.
INVULT300
INVULT400
INVULT500
5
1
INVERFLOW
ULTRA
IMP gpm
L/min
US gpm
m
3
/h