background image

Page 14

MadgeTech  PR2000

Note: Use of the Pr2000’s graphing function will reduce the battery life of the  
device, particularly when not logging.  To increase battery life either deactivate 
the graphing function by turning it to “Hide” in the Adjust Visibility screen, 
increase “auto time” in the Display Update Mode screen, or change the Graph 
Source from ‘auto’ to ‘reading’.  Alternatively, use the AC adapter for continuous 
power and graphing ability.
 

 

5.5.i.b  Display Configuration

 

  By selecting “MORE” (either by pressing the F4 key on the Adjust Visibility  
  Screen or by pressing the OK button) in the Display section the Display  
  Configuration screen can be viewed. Here LCD screen contrast values can  
  be set as well as the size the channels are displayed on the Main Screen.

 
 

Contrast

 

To change the LCD contrast view while viewing the Display Configuration  

 

screen, first select the contrast configuration parameter by pressing the  

 

F1 key. This action will highlight the function tab corresponding to  

 

the F1 key. Once this tab is highlighted the contrast can be increased  

 

or decreased using the UP and DOWN keys.

  
 

Size

 

To change the size that each channel is displayed on the Main  

 

Screen view while viewing the Display Configuration screen, first 

 

select the size configuration parameter by pressing the F2 key. This 

 

action will highlight the function tab corresponding to the F2 key. 

 

Once this tab is highlighted the size can be increased or decreased 

 

using the UP and DOWN keys. Sizes include: small, medium, and  

 large

5.5.ii  Power

The Power section displays information regarding battery and external power 
sources as well as giving options including display and backlight status that 
could potentially save power and LED status options.

 

5.5.ii.a  Power Modes

 

The power modes screen displays information regarding the display,  

 

backlight and LED mode as well as the options to change their function.

  

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание PR2000

Страница 1: ...PR2000 Data Logger Manual Red 485 Dark Blue Pantone 289 Light Blue 58 of Pantone 289 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...display units 9 4 2 Changing the number type and size of channels viewed 9 4 3 Checking the memory status 10 4 4 Checking power status 10 4 5 Changing the Contrast 10 Section 5 PR2000 Function Referen...

Страница 3: ...tion Screens Maximum Device Range 27 6 19 Device Information Screens Device Version 27 6 20 Device Information Screens Firmware Version 28 6 21 Calibration Information Screens Calibration Date 28 6 22...

Страница 4: ...ons Pressure Range 0 to 30 100 300 and 500 PSIA G 0 to 1000 and 5000PSIA Resolution 0 002 0 005 0 02 0 05PSIA G Calibrated Accuracy 2 FSR 0 25 25 C typical Dot Matrix LCD Dimensions 2 5 x 1 375 63mm x...

Страница 5: ...een use 360 days with display off Data Format Date and time stamped PSI inHg mmHg bar atm Torr Pa kPa MPa Time Accuracy 1 minute month at 20 to 30 C Computer Interface USB interface cable required 115...

Страница 6: ...atteries Except as to title this is our only warranty for the products MadgeTech Inc expressly disclaims all other warranties guarantees or remedies whether expressed or implied or statutory including...

Страница 7: ...view LED Indicators LCD Screen Pressure Sensor Power Jack Communication Jack Up Key Okay Key Down Key Cancel Key Function Keys Black anodized aluminum enclosure www GlobalTestSupply com Find Quality P...

Страница 8: ...the battery should be replaced 3 2 Memory Status Memory Memory Empty Full The memory status icons indicate the amount of memory left for data storage If the PR2000 is in wraparound mode the memory sta...

Страница 9: ...n The wait icon indicates that the device is busy 3 6 Stop Icon Indicates that the PR2000 is not currently taking readings 3 7 External Power Icon Indicates that the PR2000 is powered by an external s...

Страница 10: ...ed on a smaller or larger scale To change the number and type of displayed channels From the Main Screen press the F4 key to enter the Setup Menu and from this menu press the F1 key to enter the Displ...

Страница 11: ...e can also be viewed From the Main Screen press F4 to view the Device Configuration Menu F2 to access the power options then F4 twice to view the Power Status screen including battery power percent re...

Страница 12: ...ewed by pressing the F2 and F3 keys respec tively 5 2 i Run Parameters The Run Parameters screen displays important information regarding the device s current recording session These parameters includ...

Страница 13: ...ewing statistics by type The PR2000 s Statistics Menu also provides the option to view statistics by type This can be done by pressing F2 while in the Statistics Menu Here the function keys F1 F2 and...

Страница 14: ...ry power remaining and the presence of external power and options regarding the LCD and the backlight can be modified The setup menu is also the place to find basic information regard ing device ident...

Страница 15: ...guration parameter by pressing the F1 key This action will highlight the function tab corresponding to the F1 key Once this tab is highlighted the contrast can be increased or decreased using the UP a...

Страница 16: ...per left corner of the PR2000 can be regulated by first pressing the F3 key to highlight the LED parameter configuration tab Once the tab is highlighted the option can be changed by pressing the F3 ke...

Страница 17: ...are also found under device information including the date the device was last calibrated and when it will be due for calibration again Firmware details are also found here 5 5 iii a Device Range Mini...

Страница 18: ...firmware revision number and communications baud rate Values on this screen cannot be modified 5 5 iii e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device...

Страница 19: ...function 6 2 Status Screens Run Parameters Displays information about run parameters including date of recording start start date time of recording start start time stop date stop time recording rate...

Страница 20: ...RUN displays run parameters screen F2 MEM displays memory status screen F3 TIME displays date and time screen F4 MORE displays ID parameters screen CANCEL returns to main screen OK returns to main sc...

Страница 21: ...o function F3 MORE displays run parameters screen F4 EXIT returns to main screen CANCEL returns to main screen OK returns to main screen UP no function DOWN no function 6 6 Statistics Menu Screen Disp...

Страница 22: ...returns to Statistics Menu Screen CANCEL returns to Statistics Menu OK returns to Statistics Menu UP no function DOWN no function 6 8 Type Statistics Displays statistics from from the pressure channe...

Страница 23: ...nd start time F1 CLEAR gives the option to clear all statistics F2 no function F3 no function F4 EXIT returns to Statistics Menu CANCEL returns to Statistics Menu OK returns to Statistics Menu UP no f...

Страница 24: ...PLAY enters Adjust Visibility screen F2 POWER enters Power Modes screen F3 INFO enters Device Information screens F4 EXIT returns to main screen CANCEL returns to main screen OK returns to main screen...

Страница 25: ...n Allows the user to change the contrast of the LCD display as well as the channel size F1 CNTRST highlights the contrast parameter configuration tab F2 SIZE highlights and then changes options of the...

Страница 26: ...NCEL returns to Device Configuration Menu OK moves to Display Update Mode screen UP once parameter configuration tab is highlighted scrolls through available options DOWN once parameter configuration...

Страница 27: ...xternal voltage F1 TYPE highlights and then changes battery type Lithium or Alkaline F3 MORE moves back to Power Modes screen F4 EXIT returns to Device Configuration Screen CANCEL returns to Device Co...

Страница 28: ...e Information Screens Maximum Device Range Displays values indicating maximum pressure detectable by the PR2000 6 19 Device Information Screens Device Version Displays device version information F1 VE...

Страница 29: ...iguration Menu UP no function DOWN no function 6 21 Calibration Information Screens Calibration Date Displays date of last calibration and due date of next calibration For all Device Information Scree...

Страница 30: ...turns to Device Information screens OK returns to Device Information screens UP no function DOWN no function 6 23 Device Reset Screen Hardware Reset Displayed as notification when a hardware reset has...

Страница 31: ...rrupted during device operation F1 OK accepts notification and displays main screen F2 no function F3 no function F4 no function CANCEL no function OK accepts notification and displays main screen UP...

Страница 32: ...y insert male connector of the IFC200 interface cable into the female receptacle of the data logger WARNING Install driver before connecting a device using a USB for the first time See the Data Logger...

Страница 33: ...ld AA batteries from the battery holder and replace with six 6 new AA alkaline batteries as indicated on the holder When re placing the cover make sure that the gasket is still seated in its groove an...

Страница 34: ...supersed ed by these terms and conditions and shall not be used to interpret these terms and conditions In the event that Product includes software the software is licensed to Buyer in object code for...

Страница 35: ...or corrected during the applicable warranty period shall be in warranty for the greater of the remainder of the applicable original warranty period or ninety 90 days THE FOREGOING STATES THE SOLE AND...

Страница 36: ...THAN TWO 2 YEARS AFTER THE CAUSE OF ACTION HAS ACCRUED The foregoing allocation of risk and limitation of liability has been agreed to by the parties and forms the basis of their willingness to enter...

Страница 37: ...r alter any notice of the patent copyright or other proprietary rights related to the Software vi sub license sell lend rent or lease any portion of the Software vii copy any portion of the Software v...

Отзывы: