8
1.8 Technical specifications
Description
DN 50
DN 65
DN 80
DN 100 DN 125 DN 150 DN 200
U.M.
Accuracy class
2
Ratio Q
3
/Q
1
500:1
Maximum read-
ing
9999999.99999
99999999.99999
m
3
Maximum work-
ing pressure
1.6 (1.0 upon request)
MPa
Temperature
class
T50 (T30 upon request)
Sensitivity class
for installation
conditions
H U3-D0, V U3-D0
Protection class
IP68
Power supply
3.6 lithium battery
Vcc
Useful battery
life
13
years
Environmental
and mechanical
conditions
Class O (Class B, Class M optional)
Electromagnetic
class
MID M1, E1 (E2 on request)
Liquid
Water
Installation
position
Any
Overload flow Q
4
31,25
50,00
78,75
125,00
200,00
312,50
500,00
m
3
/h
Permanent flow
Q
3
25,00
40,00
63,00
100,00
160,00
250,00
400,00
m
3
/h
Transition flow
Q
2
0,080
0,128
0,202
0,320
0,512
0,800
1,280
m
3
/h
Minimum flow Q
1
0,050
0,080
0,126
0,200
0,320
0,500
0,800
m
3
/h
Pressure drop
25
KPa
Impulses/litres
1P=10L
1P=100L
P=L
Pulse duration
with frequency impulses generated by flow
<=4Hz 125
ms
with frequency impulses generated by flow >4Hz
half of remaining period
Содержание E-Bulk
Страница 22: ...22 6 Certified and approved...
Страница 23: ...23...