EN
21
3 Use
The normal operating phase is remote
reading of meters through radio modules.
In AMR (fixed) mode, each radio module
transmits the reading at a programmable
frequency. In mobile mode (Walk-By/Drive-
By), the radio module emits a data frame
with the measurements. To receive the ra-
dio module signal, hold a suitable receiver
near the meter. The fixed (AMR) system
reads data automatically.
l
WARNING!
Reading of data can be per-
formed using various software.
Please consult the metering op-
erator for more information on
the specific use of reading soft-
ware.
Factory
configuration
Single mode
Dual mode
wM-Bus
wM-Bus
LoRaWAN
Data sent
Tiny frame C1 (default):
current volume, date and
time, volume on billing
date, billing date, errors
Tiny frame C1 (default):
current volume, date and
time, volume on billing
date, billing date, errors
current volume, date and
time, volume on billing
date, billing date, errors,
daily consumption up to
7 previous days, alarms
Transmission time
08:00 - 18:00
08:00 - 18:00
00:00 - 24:00
Transmission
frequency
16 sec
30 secs
2 per day
Encryption
not active
not active
native
Alarms (default)
backflow (100 litres), suspected leak (observation frequency 15 min / observa-
tion period 48 hours), max flow rate (disabled)
Battery Duration
15 years
15 years