6
Power Supply
Rated power output DC24V.
Please ensure the product is connected with ground wire for safety
consideration.
Installation
Ambient temperature range: 0~50
℃
, humidity range: 35~65%RH
Avoid installing in which the ambient temperature rapidly changes.
Please check there are not volatile or inflammable material and corrosive
gases around the ionizer.
Avoid installing to the environment with heavy dust, fumes and iron
powder.
Please fasten the ionizer above the object and connect with the power,
ground wire and air pressure tube.
Please use clean air via air filter and adjust the proper air pressure at
0.1~0.5Mpa. (More detailed information please refer to specification )
After using for a period time, the needle point of electrode probe could
attach crystallized particle or dust due to moisture. If meet this problem,
please wipe the needle point of electrode probe slightly by alcohol cotton
or soft brush.
Please clean the needle point of electrode probe frequently in order to
extend the product's service life and achieve great static elimination
effectiveness.
Please contact service staff when the alarm sign shown, do not
disassemble the ionizer directly.
The ionizer with safety circuit detection, if there is abnormal adjustment it
will shut down automatically. By the time please restart the ionizer.
Due to the total length, the model above MESD-BC108 please fasten the
reinforce fixture at the mark position in order to prevent product bending.
When install longer ionizer, the model above MESD-BC180, it should be
at least two staff to complete the installation, in case of danger or product
damage.