background image

Caution and Safety

pg 1.

READ AND FOLLOW THIS MAUAL BEFROE OPERATING THE FAN.

Read these safety practices before installing, operating or servicing the fan. failure to follow these 
safety practices could result in death or serious injury.

Be certain to follow the instructions in this manual. If you do not understand the instructions please 
call our Technical department for help.

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

- Read and understand this manual before installing or operating. Installation, adjustment, reapair, 
maintenance must be performed by qualified personel.

- The user is responcable for compliance with all international and national electrical code 
requirements with respect to grounding of all equipment.

- Many of the part of this unit operat at line voltage. DO NOT TOUCH.

-Install all covers before applying power or starting and stopping the unit.

DAMAGED EQUIPMENT

Do not operate or install any fans or fan Accesory that appears to be damaged.

Failure to folow these instruction can result in death, serious injury, or equipment damage.

MAINTENANCE AND SERVICE:

If the fan does not operate properly useing the procedures in this manual, 

BE CERTAIN TO 

REMOVE ALL POWER TO THE UNIT

 and contact our technical department for futher assistance.

Keep all body clear of moving part at all times.

All electrical troubleshooting and repair must be done by a qualified technician and meet all 
applicable codes.

Содержание AirStar

Страница 1: ...TM AIRSTAR...

Страница 2: ......

Страница 3: ...Safety 2 Package Contents 3 Tools Needed 4 Fan Clearance Placement 5 I beam Mounting 6 Glulam Mounting 7 Spanning Mount Mount Assembly 8 Extention Assembly 9 Blades Blade Retainers 10 Blade Retainer...

Страница 4: ...pliance with all international and national electrical code requirements with respect to grounding of all equipment Many of the part of this unit operat at line voltage DO NOT TOUCH Install all covers...

Страница 5: ...Package Contents Power Unit Image of Hardware and Mount Remote pg 2...

Страница 6: ...ractchet deep and short wall 2 3 8 allen key 3 Magnetic level 4 Phillips and Flat Head Screw driver 5 Network crimping tool if standard connection will not work 6 Torque Wrench Not Shown Tools Require...

Страница 7: ...as placement of lights sprinklers systems HVAV systems and so on In addition OSHA requirements state that fan blade must be a minimum of 10 feet 3 05 Meters above the floor Contact our sales departmen...

Страница 8: ...beams use MacroAir I beam Kit PN 60 50106 00 To properlly install mount be sure to use hang mount along slope of the roof For ease of installation the Unistrut for our I beam mount can be installed i...

Страница 9: ...es unistrut in conjunction with our Glulam bracket for installations containing glulam beams Installation on Glulam beams will use MacroAir Glulam Mounting Kit PN 60 50108 00 Installing the mount alon...

Страница 10: ...sely install the mount hardware prior to installing fan Once the fan is installed and level tighten mount hardware down Spanning Mount also utilizes Unistrut for spanning mount installations Power Uni...

Страница 11: ...Extension Assembly Exploded View When Extension is needed assemble between mount and power unit with provided hardware refer to chart on pg 4 for size recomendations pg 8...

Страница 12: ...installing blades be sure to install the blade reatainer links by over lapping the reatainers Refer to image above for exploded view Blade bolts must be torqued to 23 ft lbs Blade Retainer Installatio...

Страница 13: ...Blade Assembly Image This image represents the correct installation of the Blade and Blade reatainer links pg 10...

Страница 14: ...ion In the case where a long CAT5 cable is required please follow the Cat5 B standard The Image above show how to route cables through extension The Image above shows the cable from the top of the Fan...

Страница 15: ...MacroAir 794 South Allen Street San Bernardino Ca 92408 p 909 890 2270...