4
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit
for additional data sheets and product information.
For further information and support please visit:
DC
-
0026742
4
MAAL-011155
Rev. V2
Ultra Low Phase Noise Amplifier
6 - 12 GHz
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
These electronic devices are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity. Proper ESD control techniques
should be used when handling these HBM Class 1A
devices.
Application Schematic
GND
GND
V
CC
GND
GND
RF
IN
V
REF
RF
OUT
100 pF
0.1
μ
F
100 pF
0.1
μ
F
Vcc
RF
IN
RF
OUT
V
REF
Operation
The technology is HBT; so, the turn
-
on and turn
-
off
procedure is fairly simple.
To turn
-
on simply:
1.
Apply +5 V to V
CC
2.
Starting at 0 V, adjust V
REF
for target I
CC
To turn
-
off:
1. Set V
REF
to 0 V
2. Set V
CC
to 0 V