1

2

Vario-louvre fittings 

Louvre end piece routed-in

Optimal slot-in position

Installation (hinging)

of fourther louvres

1

 

Place the previously 

mounted louvre at a 20° 

angle.

2

 

Align the louvres with 

the gear pins facing 

upwards in the locking 

rod and then press the 

pivoting rod downwards 

(spring-loaded) and 

allow the louvre end

        piece to snap into place.

Vario-Lamellenbeschlag 

Lamellenstück eingefräst

Optimale Einhängposition

Montage (einhängen)

der weiteren Lamellen

1

 

Bereits montierte

        Lamelle 20° zur Aus-

richtung stellen.

2

 

Die Lamellen mit dem 

Getriebebolzen nach 

oben in die Getriebe-

stange einfädeln, die 

Lagerstange nach un-

ten drücken (gefedert) 

und das Lamellenstück 

einschnappen lassen.

Содержание RUSTICO 13321

Страница 1: ...IN MOTION SHUTTER HARDWARE Vario louvre fittings Louvre end piece routed in INSTALLATIONINSTRUCTIONS TECHNIK DIE BEWEGT MACO RUSTICO Vario Lamellenbeschlag Lamellenst ck eingefr st LADENBESCHL GE MONT...

Страница 2: ...le rods 1 Turn the cropping aid as far as it will go 2 Shorten the locking rod and pivoting rod at the mark Vario Lamellenbeschlag Lamellenst ck eingefr st Abl nghilfe 3 Abl nghilfe schwen ken und ber...

Страница 3: ...aid parallel to the lockin rod and then align and mount a louvre at a 45 angle 3 Pull out the cropping aid Vario Lamellenbeschlag Lamellenst ck eingefr st Achtung Die Profilstangen d rfen in der Nut...

Страница 4: ...ing rod and then press the pivoting rod downwards spring loaded and allow the louvre end piece to snap into place Vario Lamellenbeschlag Lamellenst ck eingefr st Optimale Einh ngposition Montage einh...

Страница 5: ...rder the louvre end pieces for the selected locking side refer to the order sheet Routing jig order no 10057 Vario Lamellenbeschlag Lamellenst ck eingefr st Nutrad 100 mm 4 mm St rke Konstruktions vor...

Страница 6: ...tter height can be achieved by means of either the width of the horizontal frieze or by changing the shutter coverage on the frame or wall Please note The internal shutter dimensi on must always corre...

Страница 7: ...le rod To do so the locking rod is lifted out of the groove Important Predrill with 3 mm Carry out the operational test Vario Lamellenbeschlag Lamellenst ck eingefr st Montage des Verschlusses 2 Lamel...

Страница 8: ...Ma A in mm Dimension A in mm 13321 Gr e 1 Size 1 300 360 5 13322 Gr e 2 Size 2 420 480 540 5 13323 Gr e 3 Size 3 600 660 720 5 13324 Gr e 4 Size 4 780 840 900 5 13325 Gr e 5 Size 5 960 1020 1080 5 13...

Отзывы: