GM
390
210
M 4x16 max.
1,5 Nm
M 4x
5
max.
2,5 Nm
A
B
C
A
4
3
2
1
+
_
**
**
load
load
32
WINDOWS ·
DOORS
· SLIDING DOORS
Connections
1 GND
2 V in +8 - 24V (DC)
= supply power
3 IN COM
4 IN closed
5 IN double locked
=
Isolated free inputs
(max. load 24V / 10mA)
6 OUT 1A
7 OUT 1B
=
Isolated free outputs 1
(max. load 24V / 600mA)
8 OUT 2A
9 OUT 2B
=
Isolated free outputs 2
(max. load 24V / 600mA)
Loop for
Assembly
Plug & Play connector / cable installation
1
Brown: motor operating voltage minus -
2
White: motor operating voltage plus +
3
Green: control voltage* minus -
4
Yellow Control voltage * plus +
* The control voltage is required for push-button (button
impulse) and toggle switch (activation/deactivation of
day-release)!
openDoor Access Solutions
A-TS Somfy GU Controller
A
Motor cable connection
B
Power supply 12 - 24 V DC
min. 1.5 A
C
Tension release
12 - 24V DC
min. 1.5 A
Electrical connections (connection of power supply, connection cable 0.15 m and 10 m) may only be