Plug the power plug securely into the outlet. 
If the power plug is not securely plugged into the outlet, it may cause accidents 
involving electrical shock or fire due to heat emitted. 
Do not connect many electrical cords to a single socket or connect an AC adapter 
to an outlet that is not rated for the specified voltage. 
Doing so may cause the equipment to malfunction or fail, or lead to accidents 
involving electrical shock or fire due to heat emitted. 
Periodically  remove  any  dust  accumulated on  the  power  plug  and  around  the 
outlet (socket). 
Do not use a power plug with dust accumulated on it because doing so will lead 
to insulation failure due to moisture which may lead to fire. 
Remove any dust on the power plug and around the outlet with a dry cloth. 
Do not place any containers, such as cups or vases, filled with water or other 
liquids on the card. 
If the card is exposed to water or other liquids, it will cause a malfunction or 
electric shock. If you spilled water or other liquid on this card, immediately stop 
using the card, turn off the power, and unplug the power plug. If you have any 
requests for repairs or technical consultation, please contact the sales office you 
purchased or Mpression inquiry URL. 
Keep the card and accessories out of the reach of children. Failure to do so may 
lead to injuries. 

 

Caution

 

Do  not  place  the  card  on  unstable  places  such  as  shaky  stands  or  tilted 
locations. 
Doing so may cause injuries or cause this card to malfunction if the card should 
fall. 
Do  not  attempt  to  use  or  leave  the  card  in  places  subject  to  strong  direct 
sunlight  or  other  places  subject  to  high  temperatures  such  as  in  cars  in  hot 
weather. 
Doing  so  might  cause  the  card  to  emit  heat,  break,  ignite,  run  out  of  control, 
warp,  or  malfunction.  Also,  some  parts  of  the  equipment  might  emit  heat, 
causing burn injuries. 
Do not use the card in places subject to extremely high or low temperatures or 
severe temperature changes. 
Doing so may cause the card to fail or to malfunction. Always be sure to use the 
card within a temperature range of 5°C to 35°C and a humidity range of 0% to 
85%. 
Unplug the power supply when doing maintenance on equipment in which the 
card is embedded. 
Failure to do so may lead to accidents involving electrical shock. 
Do not place the card in locations where excessive force might be applied to it. 
Doing so may cause the printed circuit board to warp, leading to breakage of the 
printed circuit board, missing parts or malfunctioning parts. 

Содержание TI GE PHY HSMC CARD

Страница 1: ...2019 10 31 2019 Macnica Inc http www m pression com Reference Manual TI GE PHY HSMC CARD Revision A 2019 10 31...

Страница 2: ...OF THE POSSIBILITY OF SUCH DAMAGES THE TOTAL CUMULATIVE LIABILITY OF DEVELOPER IN CONNECTION WITH YOUR USE OF THE INFORMATION IN THIS DOCUMENT WHETHER IN CONTRACT OR TORT OR OTHERWISE WILL IN NO EVEN...

Страница 3: ...______________________________________________ 9 4 Functions and Features of the Card ______________________________________________ 10 4 1 Main Features 10 4 2 Product Specifications 10 4 3 Block Dia...

Страница 4: ...ware development and evaluation This card cannot be used in your mass production products Furthermore when you want to use the card s reference design for your products please be sure to confirm if it...

Страница 5: ...es where the malfunction is caused by the following reasons 1 Misuse abuse of the card or use under abnormal conditions 2 Remodeling or repair 3 A fire earthquake fall or other accidents Figures Some...

Страница 6: ...ite or the equipment in the card to fail or malfunction This may also cause fire Do not put this card or the AC adapter in cooking appliances such as microwave ovens or high pressure containers Doing...

Страница 7: ...ug If you have any requests for repairs or technical consultation please contact the sales office you purchased or Mpression inquiry URL Keep the card and accessories out of the reach of children Fail...

Страница 8: ...shock Do not clean this card by using a rag containing chemicals such as benzine or thinner Doing so could degrade the card When using a chemically treated cloth comply with its directions and warnin...

Страница 9: ...g or visibly damaged contact your sales agent within 30 days after receiving your purchase TI GE PHY HSMC CARD 1 set 5mm Spacer 2 sets 32mm Spacer 2 sets Nut 2 sets 4mm Pan Head Screw 4 sets Packing l...

Страница 10: ...Cyclone V GT FPGA development kit Refer to the following links for more detailed information and related details Information for the Cyclone V device family Documentation Cyclone V Devices Documentati...

Страница 11: ...k Diagram Figure 4 1 shows the block diagram of this card Figure 4 1 TI GE PHY HSMC CARD Block Diagram 4 4 Card Layout Figure 4 2 and Figure 4 3 show the layout of the card Figure 4 2 TI GE PHY HSMC C...

Страница 12: ...Ethernet port RJ45 Wurth Electronics 7499111000A 2 U2 Gigabit Ethernet PHY Texas Instruments DP83867IR 3 LED1 LED2 LED3 PHY status indicators Default status LED1 on Link establish LED2 on 1000BASE T l...

Страница 13: ...N HSMC_TX_D_P2 59 60 HSMC_RX_D_P2 CRS TX_ERR HSMC_TX_D_N2 61 62 HSMC_RX_D_N2 RX_ERR 3 3V 3 3V 63 64 12V 12V PWRDOWN_INT_N HSMC_TX_D_P3 65 66 HSMC_RX_D_P3 MDIO HSMC_TX_D_N3 67 68 HSMC_RX_D_N3 MDC 3 3V...

Страница 14: ...MC_TX_D_P13 131 132 HSMC_RX_D_P13 HSMC_TX_D_N13 133 134 HSMC_RX_D_N13 3 3V 3 3V 135 136 12V 12V HSMC_TX_D_P14 137 138 HSMC_RX_D_P14 HSMC_TX_D_N14 139 140 HSMC_RX_D_N14 3 3V 3 3V 141 142 12V 12V HSMC_T...

Страница 15: ...e the power is on may result in damage to or destruction of the device You need to arrange sufficient anti static prevention measures because the act of contacting the card with a person or any object...

Страница 16: ...TI GE PHY HSMC CARD 16 Reference Manual TI GE PHY HSMC CARD Macnica Inc 7 Document Revision History Date Revision Changes October 31 2019 A First Edition...

Отзывы: