E14
4. Apply thread sealant to the male threads of the hose fitting, thread the hose fitting into the
swivel, and tighten firmly.
5. Thread the new nozzle or nozzle adapter onto the extension, and tighten firmly.
6. Open all dispense position shut-off valves, and start the pump to pressurize the system. See
the Operation section for proper operation.
7. For metered dispense valves, to ensure dispensing accuracy, purge all air from the fluid
lines and dispense valves before you use them.
Grounding
Proper grounding is an essential part of maintaining a safe system.
To reduce the risk of static sparking, ground all system components per local and national
electrical codes.
Refer to the user manuals for the pump and other system components to ground the following:
1. Pump: Follow manufacture’s recommendations.
2. Air and Fluid hoses: Use only grounded hoses.
3. Air compressor: Follow manufacture’s recommendations.
4. Fluid supply container: Follow your local code.
5. To maintain grounding continuity when flushing or relieving pressure, always hold a metal
part of the valve firmly to the side of a grounded metal pail, then trigger the valve.
OPERATION
CAUTION
:
1. Never operate the meter with the plastic cover removed. The cover protects the meter from
damage due to impact. Meters are factory sealed to keep moisture and dirt out.
2. To prevent line contamination, which can cause equipment malfunction or damaged, flush
the lines before you install this equipment in the system.
Display and Button Usage
To Activate the Digital Display
1. Press the RESET key pad to clear the meter before starting a new dispense cycle. This is the
best way to activate the meter, because it also clears the quantity of the last dispense cycle.
2. The digital display can also be activated by pressing the MENU key pad or by running fluid
through the meter.
Calibrating Automatically
1. Press Reset key for 1 second and Area 1 shows .000 L;
2. Keep running fluid through the meter until the fluid running out of the certain measuring
cylinder. The display will show certain value as *.**L, press the Menu key for 3 seconds. The
meter will enter instrument calibration mode and Area 1 shows 00*.**L;
3. Press Menu key to move the flashing digital, press Reset key to choose number, enter the
fluid volume and press Menu key again for 3 seconds, then exit the calibration mode. The
calibration settled.
AREA 1: FOR LAST DISPENSE CYCLE
AREA 2: FOR MEASUREMENT UNITS
AREA 3: FOR ACCUMULATED
TOTAL
AREA 4: FOR BATTERY
CAPACITY
Notes: It will flashing when
battery voltage less than 3.3V;
Menu: MOVING THE NUMBERS FOR
ADJUSTING THE CALIBRATION AND
CHOOSING THE UNITS
Reset: CHOOSING THE UNITS AND SETTING
CORRECTION FACTOR