PROBLEMS AND SOLUTIONS

DAILY USE

• If using flexible tubing, attach the ends of the tubing to the tanks. In the absence of an 

appropriate slot, solidly grasp the delivery tube before beginning dispensing.

• Before starting the pump make sure that the delivery valve is closed (dispensing nozzle or 

line valve).

• Turn the ON/OFF switch to ON. The by-pass valve allows functioning with the delivery closed 

for only brief periods.

• Open the delivery valve, solidly grasping the end of the tubing.

• Close the delivery valve to stop dispensing.

• When dispensing is finished, turn off the pump.

MAINTENANCE

Under normal working conditions the noise emission from all models does not exceed the value 

of 80 db at a distance of 1 meter from the electric pump.

E3

TECHNICAL

DETAILS

SAFETY

PRECAUTIONS

OPERATION

EXPLODED AND

PARTS LIST

INSTALLATION

MAINTENANCE

LIMITED

WARRANTY

PROBLEMS AND

SOLUTIONS

Problem

The motor is not 
turning

Low or no flow rate

Increased pump 
noise
Leakage from the 
pump body

Possible Cause

Lack of electric power
Rotor jams

Motor problems
Thermal overload protection shut
Low level in the suction tank
Foot valve blocked
Filter clogged
Excessive suction pressure
High loss of head in the circuit 
(working with the by-pass open)
By-pass valve blocked
Air entering the pump or the 
suction tubing
A narrowing in the suction Tubing
Low rotation speed

The suction tubing is resting on the 
bottom of the tank
Cavitations occurring
Irregular functioning of the by-pass
Air present in the diesel fuel
Seal damaged

Corrective Action

Check the electrical connections and the safety systems
Check for possible damage or obstruction of the 
rotating components.
Contact with the service department
Move ON/OFF lever to the “OFF” position to reset pump.
Refill the tank
Clean and/or replace the valve
Clean the filter
Lower the pump with respect to the Level
Use shorter tubing or of greater Diameter

Dismantle the valve, clean and/or replace it
Check the seals of the connections

Use tubing suitable for working under suction pressure
Check the voltage at the pump.
Adjust the voltage and/or use cables of greater 
cross-section
Raise the tubing

Reduce suction pressure
Dispense until the air is purged from the circuit
Verify the suction connections
Check and replace the mechanical seal

Содержание FTP120-001

Страница 1: ...re operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read wh...

Страница 2: ...ere are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this...

Страница 3: ...to the OFF position to reset pump WARNING 1 Electrical wiring should be done a licensed electrician in compliance with local codes Rigid conduit should be used and proper ground must be provided to a...

Страница 4: ...8 3 Strip 6in of the outer covering from one end of the furnished electrical cable being careful not to damage the black and red wire insulation 8 4 Loosen cable connector nut and pass the stripped e...

Страница 5: ...ms Thermal overload protection shut Low level in the suction tank Foot valve blocked Filter clogged Excessive suction pressure High loss of head in the circuit working with the by pass open By pass va...

Страница 6: ...prepaid to the distributor or their designated service depot 3 The warranty does not cover damage caused by accident misuse or faulty installation 4 The product must be installed and maintained in co...

Страница 7: ...ge hose Elbow Bypass spring Electric motor Pump chamber Bypass valve O ring Filter screen 2 Bung adapter Screw Suction tube Q ty 6 1 1 5 5 1 1 1 1 1 1 1 1 1 1 1 1 2 1 Part No 20 21 22 23 24 25 26 27 2...

Страница 8: ...Macnaught Americas 813 628 5506 info macnaughtusa com Read Manual Before Use...

Отзывы: