Macnaught 050 Скачать руководство пользователя страница 3

 

Page 3 of 14 

Maintenance Procedures 

Disassembly - Flow Meter 

Ensure  that  the  fluid  supply  to the meter is  
disconnected,  and  the  line pressure is released  
before disassembly.   
Refer  to  the  exploded  parts  diagram  and  parts  list, 
for item numbers. 
 
1) Remove the four screws located on the face of the 
  register.  Then  remove  the  face  plate  cover 
  including register assembly.  
 
2)  Remove  the  four  register  mounting  screws  and 
 

remove the lower half of the register housing. 

 
3) Remove the six cover plate screws (Item 12) and 
 

remove the cover plate (Item 11). 

 
4)  Remove  the  six  meter  cap  screws  (Item  5)  and 
 

remove the meter cap (Item 4). 

 
5) Remove rotors (Item 3). 

Reassembly - Flow Meter 

 
1)  Before  reassembling  check  the  condition  of  
 

the  rotors  (replace  if necessary). 

 
2) Check  that  the  smooth  side  of  the rotors  (not  
 

the    plug    side)    is    facing  you    when    inserting  

 

the  rotors,  the smooth  side  of  the  rotor  is  the 

 

magnet side. There is no difference between rotor 

 

one or rotor two. 

 
3) Replace the rotors (Item 3) onto the shafts at  90 
 

degrees    to  each  other  (refer  Fig)    and    check  

 

their  operation  by turning  either  of  the  rotors.   

 

If  the rotors  are  not  in  mesh  correctly  or do  

 

not    move    freely,    remove    one    of  the    rotors  

 

and  replace  correctly  at 90 degrees to the other 

 

rotor.  

 
4) Re-check the operation of the rotors 
 
5)  Inspect the gears (Item 6) in the meter cap (Item 
 

4) for wear. (Replace if required, refer to parts on 

 

page 4)  

 
6)  Replace  the  o’ring  (Item  2)  into  groove  In  the 
 

meter cap, if the o’ring has grown or is damaged 

 

in any way replace it with a new part. 

 
7) Replace the meter cap making sure that the gear 
 

on the rotor is meshing correctly with the gear in 

 

the  meter  cap  (Item  4).  Insert  the  cap  head  

 

screws  (Item  5)  and  tighten  in  a  diagonal 

 

sequence 1, 4, 2, 5, 3, 6. 

 
8) Replace the cover plate inspect the o-ring  
  (item  10),  bevel  gear  (Item  7),  for  wear  or 
  damage. (Replace if necessary). 

Содержание 050

Страница 1: ...and operating instructions for meters with Mechanical Displays If you need further assistance contact your local representative or distributor for advice This Flow Meter has incorporated the oval roto...

Страница 2: ...switches or Hall Effect sensors A signal is generated which is then sent by the Pulse Circuit Board PCB to the relevant LC display or receiving instrument 1 It is recommended that when setting up pip...

Страница 3: ...when inserting the rotors the smooth side of the rotor is the magnet side There is no difference between rotor one or rotor two 3 Replace the rotors Item 3 onto the shafts at 90 degrees to each other...

Страница 4: ...d maximum flow rates b Bleed air from system c Check meter body and rotors Replace as required Refer to installation instructions Fluid flows but no reading on meter a Bevel gear is loose on shaft b R...

Страница 5: ...Description 1 Meter Body 2 Meter Cap 0 Ring 3 Rotor Set 4 Adaptor Bolts 5 Flanged Process Connection 6 Adaptor O Rings 7 Threaded Process Connection 8 Meter Cap 9 Gear Set 10 Meter Cap Screws 11 Cover...

Страница 6: ...g Procedure 1 Determine what type of Spare Parts Kit is required e g Rotor Kit 2 Use the Coding Sequence to construct a part number according to the meter type Flange Seal Kit FSKit FSKit Type Size F...

Страница 7: ...umber Order Number Components Qty Items Cover Plate O Ring 1 e g SKit F050 M 11 Meter Body O Ring 1 2 Order Number Components Qty Items Complete Rotor Assembly 1 set e g RKit F050 SM 3 Meter Body O Ri...

Страница 8: ...de POM Acetal PTFE Polytetrafluoroethylene FFKM Perfluoro Elastomer Component Type F Type S Type M Meter Body Al Al SS Rotor Shaft SS SS SS Rotors Standard PPS SS PPS High Temp SS High Viscosity PPS S...

Страница 9: ...Page 9 of 14 Pressure Drop v s Viscosity 100 50 25 10 5 100 50...

Страница 10: ...Page 10 of 14 Meter Dimensions...

Страница 11: ...Page 11 of 14 Air Eliminator Strainer Combination 2 Flange 2 Threaded Connection...

Страница 12: ...Page 12 of 14 Notes...

Страница 13: ...ies of purchase receipts and or other supporting documents and at the purchaser s own cost returning the defective product to the nearest authorised Macnaught service centre Subject to compliance by t...

Страница 14: ...Page 14 of 14...

Отзывы: