Cleaning 

Please follow the cleaning guidelines below on cleaning and disinfecting the Stand Aid. 

 

General Cleaning 

 
It is recommended to clean the Mackworth SA180 and accessories before use by a different person, reducing the risk of 
cross

contamination. 

 
The exterior of the Mackworth SA180 can be cleaned using a damp soapy cloth for general cleaning duties. Please ensure the 
cloth is damp and not wet. Ensure the exterior of the device is dry after cleaning. Dry using a clean dry cloth. 

 

Disinfecting (if necessary) 

Should the Stand Aid require a more thorough clean, the use of the Actichlor

 disinfectant product (which is widely available in 

tablet form and used throughout the health care industry) is recommended. 
 

Follow the manufacturer’s safety instructions for the use of the cleaning product before use to ensure safe use for the 

operator and the patient. 
Ensure the cloth is damp before the cleaning process.  

 
Application is through a clean damp cloth applied to wipe the device down. Use in the following dilutions to ensure an effective 
clean: 
 

 

Actichlor

 dissolvable chlorine tablets provide a concentration of 1000 ppm of available chlorine (0.1%) per 1 tablet 

 

1 tablet (1.7g formed tablet (x1)) will create a virucidal solution, diluted in 1 litre of water to provide effective means to 

clean a “dirty” device. This is also ideal for use after an outbreak of the Norovirus/winter vomiting and can be used as a 

precaution against C.Diff. It is effective against viruses, bacteria, spores, yeasts and moulds. 

 

The contact time against the outer components of the device should be for 5 minutes to prevent any virucidal 
infections without a degradation to the functionality of the device. 5 minutes is a recommended contact time. The 
device can withstand a longer contact period but the 5 minute recommendation as a minimum must be followed to 
provide an effective cleaning regime. 

 

Blood spills should be dealt with by an increased concentration of the solution 

 please refer to the instructions on the 

manufacturers product labelling. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SA180

Страница 1: ...Doc No 993065 Revision of document A Revision Date 25 05 21 SA180 Stand Aid Pre Sales Document...

Страница 2: ...Slings 4 Detachable Parts 5 Attaching detaching the Battery 5 Technical Specification 6 Mackworth SA180 Dimensions 6 Specifications 7 Electrical Specifications 7 Environmental Storage and Operating C...

Страница 3: ...gned to support and promote safe patient handling and transfer for both the patient and carer The Stand Aid is one of two components that makes this possible The other component the sling is a special...

Страница 4: ...e been approved by Prism Medical UK for use in combination with the product We recommend the use of the Mackworth Healthcare or Care Ability manufactured sling range type B applied part to be utilised...

Страница 5: ...ment and detachment of the Battery can be completed safely by following the following procedure Attach 1 Grab Hold of the Battery from the top position as shown in figure 5 and place your fingers onto...

Страница 6: ...993065 Revision A P a g e 6 of 12 Technical Specification Mackworth SA180 Dimensions All dimensions below are shown in millimetres Figure 8 Figure 9...

Страница 7: ...rical Specifications Battery type 2 x 12 volt Rechargeable sealed lead acid Battery capacity 24 V DC 1 x 2 9 Ah Charger rated input 230VAC 50 60Hz Charger rated output 27 4 29 0 VDC 0 8A Electric Shoc...

Страница 8: ...ty is void To ensure the safety and continued good function of your Stand Aid routine service must be performed on your Mackworth SA180 Stand Aid Service should be completed by a Prism Medical UK appr...

Страница 9: ...cleaning process Application is through a clean damp cloth applied to wipe the device down Use in the following dilutions to ensure an effective clean Actichlor dissolvable chlorine tablets provide a...

Страница 10: ...993065 Revision A P a g e 10 of 12...

Страница 11: ...993065 Revision A P a g e 11 of 12...

Страница 12: ...UK for any errors or omissions Prism Medical operates a policy of continuous improvement Specifications and other data are subject to change without notice Manufacturer contact details Prism Medical U...

Отзывы: