995051 – Revision A
Page 24 of 36
9.6 – Leg Actuator
Within this section it will explain the correct procedure on removing and reinstalling the Leg
Actuator for servicing procedures or replacement.
Removal
Step 1 – Remove the Leg Actuator Cable. (Refer to section 9.2.3)
Step 2 – Remove the four Black Caps from the Actuator fixing points.
Step 3 – Using two 13mm Spanners, remove a nut from the fixing pin. Repeat for the second
fixing point.
Step 4 – Slide the pin out to release the Actuator. Repeat for the second fixing point.
Refitting / Replacement
Step 4 - Refitting is a reversal of the removal process noting the following point:
A)
Ensure the Actuator is fitted in the correct orientation, with the label facing the floor
and the Piston end fixture attached to the Leg, as shown in the image in Step 2.