Safety First!

Before connecting and using the

equipment, please read this Quick-Start Guide
carefully and keep it for future reference.

WARNING!

 This equipment has been

designed to be installed by qualified
professionals only! There are many factors to
be considered when installing professional
sound reinforcement systems, including
mechanical and electrical considerations, as
well as acoustic coverage and performance.
Mackie Industrial strongly recommends that
this equipment be installed only by a
professional sound installer or contractor.

Part No. 910-142-20  Rev. B  10/01
© 2001 Mackie Industrial. All Rights Reserved. Printed in U.S.A.

CAUTION:

 To avoid the risk of electric

shock, never allow this equipment to
be exposed to rain or dampness.

UP4000 Series

Power Amplifier

Quick-Start Guide

The UP4000 Series Power Amplifiers are

designed for continuous duty in speech,
music, paging, and sound reinforcement
applications in churches, schools, offices, and
other venues demanding high performance,
flexible features, and rugged dependability.

Two discrete inputs with priority are

provided. The main program input is actively
balanced and terminated to a barrier strip
connection on the rear panel. The second
input is unbalanced and terminated to a
single RCA connector. A contact closure will
give priority to the balanced input by muting
the unbalanced input. The unbalanced input
features a parallel output and 0/–20 dB
sensitivity switch.

Output modes include 4

 constant

impedance and 25V, 50V, 70V, and 100V
constant voltage. The smart output stage is
fully protected against permanent damage
caused by overloading, shorts, and extreme
temperatures. Activation of the overload
protection circuit turns on 18 VDC (300mA)

power at a barrier connector on the rear panel,
which may be used to drive LEDs or relays.
The UP4000 Series operates on either 115 VAC
or 230 VAC, 50/60Hz, as determined by the
Voltage Selector switch, and supplied by a
detachable IEC power cord. Insulated
terminals to connect a backup 24 VDC battery
are provided on the rear panel. Switchover to
DC is automatic. A programmable stand-by
mode allows the amplifier to be turned on
remotely with a contact closure.

The front panel provides a Master volume

control, and Low and High EQ controls. The
control knobs can be removed for security,
and their recessed shafts covered with the
supplied inserts. LEDs indicate power, stand-
by mode, signal present at the output, peak,
and output overload. 12 dB/octave Low and
High shelving equalization with up to 12 dB of
boost or cut at 100Hz and 10kHz can be
applied to the output signal.

Accessories include a rack mounting kit.

The 

STAND BY

 terminal is used to turn on

the amplifier with a remote switch.

Note:

 Standby mode must first be

activated by moving a jumper (J1) on the
input board (standby mode is disabled by
default). See Figure 1 on back page.

When the POWER switch is turned on, the
amplifier goes into standby mode. In this
state, the amplifier is on but signal is not
allowed to pass. Shorting the STAND BY
terminal to the GND 

 terminal with an

external switch causes the amplifier to
become fully operational.

The 

STANDBY GND

 terminal on the

COMMANDS terminal strip is the common
connection point for STAND BY.

The 

OVERL. 300mA

 terminal is active

whenever the amplifier's overload
protection circuit is activated. This
provides 18 VDC with a maximum output
capacity of 300mA for driving an auxiliary
relay or indicating LED.

The 

OVERL. GND

 terminal on the

COMMANDS terminal strip is the common
connection point for OVERL. 300mA.

AC Protection Fuse protects the power
supply and amplifier circuitry. Replace
only with same type fuse.

Connect the supplied AC linecord to the
IEC AC Socket. The AC line fuse is

1. Never install, connect, or disconnect

the unit with the power supply on.

2. Before powering up the UP4000 Series

amplifier, make sure the voltage
selector switch on the rear panel
corresponds to the AC voltage applied.

3. Make sure the safety ground on the

power cord is properly grounded.

4. To prevent the risk of electric shock,

never open the unit. There are no
user-serviceable parts inside.

5. To ensure normal cooling of the

UP4000 Series, make sure the unit is
well-ventilated. Avoid exposure to direct
sunlight or proximity to any heat
source, dust, or dampness.

6. If installed in an equipment rack, provide

at least one rack space between each
integrated amplifier.

LOW

EQ

HIGH

VOLUME

0

10

8

2

1

3

4

5

6

7

9

8

4

2

0

2

4

8

-10

+10

6

6

8

4

2

0

2

4

8

-10

+10

6

6

POWER

PEAK

OVERLOAD SIGNAL

ON

STD-BY

UP 4161 - P.A. AMPLIFIER

contained in the socket, behind the cover
located at the bottom of the socket.
Replace only with same type fuse.

The 

VOLTAGE SELECTOR

 switch is used to

select the AC supply voltage for the
amplifier. Move switch so the AC line
voltage used appears on the switch
(DOWN for 115V, UP for 230V).

The 

H.P.

 switch activates a high-pass filter

on INPUTS 2-4, which attenuates
frequencies below 300Hz at 12 dB/octave.

The 

L.P.

 switch activates a low-pass filter

on INPUTS 2-4, which attenuates
frequencies above 7kHz at 12 dB/octave.

The 

UNBALANCED IN 

jack is an RCA-type

connector that can be used instead of the
BALANCED IN, or both can be used with
the PRIORITY function, which gives the
BALANCED IN priority over the
UNBALANCED IN.

The 

PARALLEL OUT

 jack is an RCA-type

connector that is in parallel with the
UNBALANCED IN jack for connecting to the
input of another power amplifier.

The 

SENSITIVITY

 switch adjusts the input

sensitivity of the UNBALANCED IN from 0
dB (typical line-level signals) to –20 dB
(for low-level signals).

J1

1

2

3

STANDBY DISABLED
(DEFAULT)

STANDBY ENABLED

JP6

UP4000 SERIES

INPUT BOARD

Fig. 1: UP4000 Standby Mode Jumper (J1)

 

 

 

Содержание UP 4000 Series

Страница 1: ...erload protection circuit turns on 18 VDC 300mA power at a barrier connector on the rear panel which may be used to drive LEDs or relays The UP4000 Series operates on either 115 VAC or 230 VAC 50 60Hz as determined by the Voltage Selector switch and supplied by a detachable IEC power cord Insulated terminals to connect a backup 24 VDC battery are provided on the rear panel Switchover to DC is auto...

Страница 2: ...LOW EQ HIGH VOLUME 0 10 8 2 1 3 4 5 6 7 9 8 4 2 0 2 4 8 10 10 6 6 8 4 2 0 2 4 8 10 10 6 6 POWER PEAK OVERLOAD SIGNAL ON STD BY UP 4161 P A AMPLIFIER ...

Страница 3: ...CTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIF...

Страница 4: ...is approaching clipping The ON indicator lights when the AM4000 is turned on and ready for operation Front Panel Features LOW EQ is a shelving filter that provides 12 dB of boost and cut below 100Hz HIGH EQ is a shelving filter that provides 12 dB of boost and cut above 10kHz VOLUME is a master volume control used to adjust the overall volume of the signal at the POWER OUTPUTS Use the POWER switch...

Страница 5: ...he unit is not equipped with battery charging capability The D C FUSE protects the DC POWER INPUT circuit Replace with the same type fuse only POWER OUTPUTS are screw terminal connections for connecting speakers to the 4 ohm 25V 50V 70V or 100V outputs WARNING To prevent the risk of electric shock never touch the bare wires coming from the output terminals of the amplifier when it is switched on W...

Страница 6: ...each speaker must be equipped with a line transformer having an input voltage equal to that of the line e g 25V 50V 70V or 100V Typically these line transformers have selectable power taps i e 2 5W 5W 10W for connecting to the constant voltage line CAUTION The sum of the wattage values of the speakers must not exceed the output power of the amplifier Connect the appropriate POWER OUTPUT voltage te...

Страница 7: ... an external normally open switch connected between the PRIORITY terminal to the GND ground terminal The ground terminal is internally connected to the chassis and safety ground on the AC linecord The PRIORITY terminal activates the priority function for the BALANCED IN by using an external normally open switch to short circuit the PRIORITY terminal to the GND ground terminal When the PRIORITY fun...

Страница 8: ...an auxiliary relay or indicating LED The OVERL GND terminal on the COMMANDS terminal strip is the common connection point for OVERL 300mA AC Protection Fuse protects the power supply and amplifier circuitry Replace only with same type fuse Connect the supplied AC linecord to the IEC AC Socket The AC line fuse is contained in the socket behind the cover located at the bottom of the socket Replace o...