Mackie UP 4000 Series UP4121 Скачать руководство пользователя страница 2

Power Amplifier

UP4121

AMPLIFIER

UP4121

oF 6 PAGES

2

O F   4   P A G E S

Specifications

Performance

Amplifier Power:

120W, nominal, 180W peak (10mS)

Frequency Response:

50Hz–15kHz ±3dB

Distortion:

Less than 1% THD at 1kHz

nominal power

Noise:

Better than 80dB

Equalization

Output:

Treble shelving: ±12 dB at 10kHz, 

Bass shelving: ±12 dB at 100Hz

Inputs:

H-P filter: 12dB/oct. at 300Hz, 

L-P filter: 12 dB/oct. at 7kHz

Audio Inputs

Line Level, Balanced:

775mV, 100k

, barrier connector

Line Level, Unbalanced:

775mV, 50k

or 80mV, 

50k

, RCA connector

Audio Outputs

Number of Channels:

One

Impedance:

4

Constant Voltage:

One each, 25V, 50V, 70V, 

100V, barrier connectors

Line Level:

Parallel to Unbalanced In, RCA connector

Control Inputs & Outputs

Outputs: Overload Indicator:

18Vdc (300mA)

Inputs: Priority Switch Input:

Dry contact closure

Stand-by Switch Input:

Dry contact closure, 

barrier connectors

Controls

Front Panel:

Power switch, master Volume, 

Treble shelving, Bass shelving

Rear Panel:

Unbalanced input sensitivity switch, 

H-P Filter in/out switch, 

L-P Filter in/out switch, 

Mains Voltage Selector switch

Power Supply

115/230VAC (±5%), 50/60Hz, 450VA, 

DC (24V battery) 10A/Hr

Environment

Maximum Ambient:

131°F (55°C), 

Non-precipitating humidity

Physical

Dimensions (HxWxD):

3.46" x 17" x 12.4"

(88mm x 433mm x 315mm)

Weight:

30.5 lbs. (11.4kg)

Finish:

Black painted or treated 

steel, white nomenclature

Warranty

3 years, parts & labor

one-time, no-fault repair policy

Содержание UP 4000 Series UP4121

Страница 1: ...ge The output stage is fully pro tected against permanent damage caused by overload ing shorts and extreme temperatures The UP4121 will operate on either 115 or 230VAC 50 60Hz supplied by a detachable IEC power cord Insulated terminals to connect a back up 24Vdc battery are provided on the rear panel Switchover to DC is automatic A programmable stand by mode allows the amplifier to be turned on re...

Страница 2: ... 50V 70V 100V barrier connectors Line Level Parallel to Unbalanced In RCA connector Control Inputs Outputs Outputs Overload Indicator 18Vdc 300mA Inputs Priority Switch Input Dry contact closure Stand by Switch Input Dry contact closure barrier connectors Controls Front Panel Power switch master Volume Treble shelving Bass shelving Rear Panel Unbalanced input sensitivity switch H P Filter in out s...

Страница 3: ... IN ITALY PATENTS PENDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE MÊ ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE CO...

Страница 4: ...anel An overload condition shall cause an auxiliary voltage of 18Vdc at 300mA to be present at a pair of terminals on the rear panel The unit shall have on its front panel continuously vari able controls for master volume as well as bass and treble shelving filters The shelving filters shall have a range of 12dB with the frequency for the bass fixed at 100Hz and the treble fixed at 10kHz LED statu...

Отзывы: