8
7
Place the new amp assembly (part
#0005687) where the old one was. Follow
the same steps as above, but backwards
6 to 1. Remove the serial number from
the faulty amp assembly (as shown in
picture above) and place on the new
amp assembly. Power up the SWA1801
and relish in the fact that you just
replaced an amp assembly. Hats off to
you for a job well done!
6
Two cables need to be removed from
the amp assembly: (1) woofer cable
(positive and negative cables on one
connector) and (2) led PCB cable. Do
not force cable removal or connection.
Notice their placement, as well -- black
wire of led PCB cable and yellow and
black woofer cable are both closer
towards the edge of the amp assembly.
Amp assembly replacement continued:
5
It may be easier to remove the amp
assembly if the cabinet is on its side. Do
not completely remove amp assembly
yet, as cables need to be removed fi rst.
Caution:
amp assembly is approximately
20 pounds, so please make sure to grasp
it fi rmly.
8
Important:
The faulty amplifi er
assembly must be returned to LOUD
Technologies. The address should be
on the return shipping label that was
provided with the new amp assembly.
If not, the return address is at the top of
this page. Also, please write the order
number and service request number
(ex: 1046256-1203935) in big, black, bold
numbers on the outside of the box. This
helps expedite the return.
11
2
Содержание SWA1801