Mackie Onyx 800R Скачать руководство пользователя страница 5

5

Owner’s Manual

Owner’

s Manual

Getting Started

READ THIS PAGE!!

Even if you’re one of those people 
who never reads manuals, all we ask 
is that you read this page now before 
you begin using the Onyx 800R. You’ll 
be glad you did!

Zero the Controls

1.  Turn down the channel GAIN controls.

2.  Set all push button switches to their “out” positions.

3.  Turn the POWER switch off.

Connections

If you already know how you want to connect the 

Onyx 800R, go ahead and connect the inputs and 
outputs the way you want them. If you just want to get 
sound through the preamp, follow these steps:

1.  Plug a microphone into channel 1’s MIC input.

2.  Connect the analog line outputs to your MDM, HDR, 

or audio interface for your DAW. This requires ei-
ther a DB25-to-DB25 audio cable or a DB25 break-
out cable to either eight male XLR plugs or eight 
1/4" TRS plugs.

3.  You can connect the Toslink OPTICAL OUT connec-

tors to your recording equipment if they are equipped 
with Toslink ADAT optical connectors. All eight chan-
nels are always present at the LINE LEVEL OUTPUTS 
and the OPTICAL OUTs up to 96 kHz sampling (four 
channels at the OPTICAL OUTs at 176.4/192 kHz).

4.  You can connect the DB25 AES/EBU OR S/PDIF 

OUT connector to your recording equipment if they 
are so equipped, but we recommend that you fi rst 
read the section on pages 14-15 that describes this 
output and its associated buttons.

 

Note:

 When using the OPTICAL OUTs or the AES/EBU 

OR S/PDIF OUT, make sure your MDM, HDR, or other 
audio interface is confi gured to clock off the incom-
ing digital source. If you try to use their internal 
clocks, it’s simply not going to work right.

5.  Plug in the detachable linecord, connect it to an AC 

outlet, and turn on the Onyx 800R’s POWER switch.

6.  If the microphone is a dynamic microphone, set the 

impedance switch on channel 1 to the “D” position 
(2400 

). If it’s a condenser microphone, set the 

impedance switch to the “D” position (or to the 
manufacturers recommended impedance setting) 
and push in the 48V phantom power button to turn 
on the phantom power for channel 1.

Set the Levels

To set the channel GAIN controls, it’s not even neces-

sary to hear what you’re doing at the outputs of the 
preamplifi er. The following steps must be performed one 
channel at a time.

1.  Play something into the selected input. This could 

be an instrument, a singing or speaking voice, or 
a line input such as a CD player or tape recorder 
output. Be sure that the volume of the input source 
is the same as it would be during normal use. If it 
isn’t, you might have to readjust these levels later.

2.  Adjust the channel’s GAIN control so that the “–20” 

and “0” LEDs light frequently or continuously, and 
the “OL” LED doesn’t light at all (or only fl ashes 
occasionally).

3.  Repeat for each channel.

Start Recording

1.  You should now see the signals from the Onyx 800R 

appearing on the meters in your MDM, HDR, or 
DAW. Start recording and hear the Onyx 800R in 
stunning crystal clarity.

Other Nuggets of Wisdom

• 

You can connect the analog outputs from any line-
level source to the LINE LEVEL INPUTS on the 
Onyx 800R and use its high-quality analog-to-digital 
converters to get your analog signals to your digital 
recorder(s).

•   Always turn the Onyx 800R off before making or 

changing connections.

•   When you shut down your equipment, turn off the 

amplifi ers fi rst. When powering up, turn on the 
amplifi ers last.

•   Never listen to loud music for prolonged periods. 

Please see the Safety Instructions on page 2 for 
information on hearing protection.

•   Save the shipping box! You may need it someday, 

and you don’t want to have to pay for another one.

That’s it for the “Getting Started” section. Next comes 

the “Hookup” section that shows you some typical ways 
that you might use the Onyx 800R in real applications. 
After that, you can take the grand tour of the Onyx 800R, 
with descriptions of every knob, button, input, and output. 
We encourage you to take the time to read all of the 
feature descriptions, but at least you know it’s there if 
you have any questions.

Содержание Onyx 800R

Страница 1: ...O W N E R S M A N U A L PREMIUM EIGHT CHANNEL MICROPHONE PREAMP w 192 kHz DIGITAL OUTPUT...

Страница 2: ...xposed to sufficiently intense noise for a period of time The U S Government s Occupational Safety and Health Administration OSHA has specified the permissible noise level exposures shown in the follo...

Страница 3: ...ontrols 5 Connections 5 SettheLevels 5 StartRecording 5 HookupDiagrams 6 Onyx800RFeatures 10 FrontPanel 10 RearPanel 12 AppendixA ServiceInformation 16 WarrantyService 16 Troubleshooting 16 Repair 17...

Страница 4: ...are also provided on a DB25 connector Digital outputs are provided on two optical Toslink connectors using the ADAT lightpipe digital audio format AES EBU or S PDIF formats are available on a DB25 co...

Страница 5: ...e D position or to the manufacturers recommended impedance setting and push in the 48V phantom power button to turn on the phantom power for channel 1 Set the Levels To set the channel GAIN controls i...

Страница 6: ...IC PRE ONYX MIC PRE MID SIDE DECODE TERMINATION OFF ON 75 EXTERNAL WORD CLOCK IN Mics Digital I O for Workstation OPTICAL or AES EBU OR S PDIF To Desktop or Laptop Computer Input 8 Input 1 Drum Machin...

Страница 7: ...UMER 100 240 VAC 50 60Hz 105W 8 7 6 5 4 3 2 1 110 75 NORMAL MID SIDE PRO CONS DUAL WIRE SINGLE WIRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC...

Страница 8: ...110 75 NORMAL MID SIDE PRO CONS DUAL WIRE SINGLE WIRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE MID SIDE DECODE TERMINATION OFF ON 75 EXT...

Страница 9: ...IRE SINGLE WIRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE ONYX MIC PRE MID SIDE DECODE TERMINATION OFF ON 75 EXTERNAL WORD CLOCK IN Vocal Mics Onyx 800...

Страница 10: ...re very sensitive to the input impedance of the mic preamp and operate best at specific impedances The MIC IMPED ANCE switch allows you to change the input impedance of the microphone inputs on channe...

Страница 11: ...ch serves to convert the impedance of the guitar from high to low The HI Z inputs on channels 7 and 8 make the need for a direct box unnecessary HOWEVER The HI Z inputs are unbalanced so if you re doi...

Страница 12: ...king Another benefit of this recording technique is that the stereo recording is mono compatible This is especially important for broadcast and film produc tion applications A number of stereo recordi...

Страница 13: ...on button out on all the Onyx 800Rs except for the last one in the chain Remember the last device in the chain is the one that should be terminated with 75 ohms 16 BALANCEDLINELEVELINPUT This is a DB2...

Страница 14: ...ofessional AES EBU format or the consumer S PDIF format Note Strictly speaking AES EBU can transmit up to 24 bits while S PDIF is limited to 20 bits because four bits are reserved for user bits Howeve...

Страница 15: ...h to the SINGLE WIRE position This transmits two channels on a single wire 3 pin XLR at twice the speed 88 2 96 kHz or four times the speed 176 4 192 kHz When connecting to devices that use the double...

Страница 16: ...rce is causing the problem Sometimes it helps to plug all the audio equipment into the same AC circuit so they share a common ground Make sure you are using shielded cable designed for digital audio t...

Страница 17: ...to non factory packaging 5 Include a legible note stating your name shipping address no P O boxes daytime phone number RA number and a detailed description of the problem including how we can duplica...

Страница 18: ...nec tions are wired to each other and that the balanced signal low cold goes to the ground earth connection at the unbalanced input In most cases the balanced ground earth will also be connected to th...

Страница 19: ...r audio with proper shielding to reduce crosstalk and noise DB25 cables that break out to XLR 1 4 TRS or TT connectors for connecting to other mixers or audio gear are also readily available See your...

Страница 20: ...mits AES EBU or S PDIF formatted digital audio with single wire dual wire options available at all sample rates Appendix C Technical Info Onyx 800R Specifications Frequency Response Mic Input to Line...

Страница 21: ...always striving to improve our prod ucts by incorporating new and improved materials components and manufacturing methods Therefore we reserve the right to change these specifications at any time wit...

Страница 22: ...D Conversion Pro Consumer Single Dual Wire ADAT ADAT 48V Channel 1 Mic Line Gain Mic 0 to 60 dB Line 20 to 40 dB Hi Z Mic Line Hi Z 2 3 1 300 500 1300 2400 Mic Impedance Line Mic 48V Channel 2 Mic Lin...

Страница 23: ...packing can be found in the Service section of this manual 5 Contact the Authorized Mackie Service Center to arrange service or bring the Mackie product to them F LOUD Technologies and Authorized Mac...

Страница 24: ...Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail s...

Отзывы: